Michael Chus f87461ee4a Detect thermal throttle with fans below 100% as cooling misconfiguration
During power calibration: if a thermal throttle (sw_thermal/hw_thermal)
causes ≥20% clock drop while server fans are below 98% P95 duty cycle,
record a CoolingWarning on the GPU result and emit an actionable finding
telling the operator to rerun with fans manually fixed at 100%.

During steady-state benchmark: same signal enriches the existing
thermal_limited finding with fan duty cycle and clock drift values.

Covers both the main benchmark (buildBenchmarkFindings) and the power
bench (NvidiaPowerBenchResult.Findings).

Co-Authored-By: Claude Sonnet 4.6 <noreply@anthropic.com>
2026-04-14 21:44:57 +03:00
2026-04-08 07:14:31 +03:00
2026-03-15 22:07:42 +03:00