Mikhail ChusavitinandClaude Sonnet 5 76db45ee95 feat(audit): capture IPMI FRU/Elabel, mc info and LAN on every audit
The techdump — the only place the IPMI FRU / Elabel identity (Product Name
= server model, serials, part numbers) is recorded — only ran under LiveCD.
Run it on every audit so `bee audit` on an installed host captures it too.

Also add `ipmitool mc info` and `ipmitool lan print` to the techdump, and
pin `ipmitool fru print 0` to FRU device 0 to match the Export Tools
"FRU / Elabel" editor exactly.

Co-Authored-By: Claude Sonnet 5 <noreply@anthropic.com>
2026-09-03 15:18:01 +03:00

266 lines
10 KiB
Go

package platform
import (
"encoding/json"
"os"
"os/exec"
"path/filepath"
"sort"
"strings"
)
var techDumpFixedCommands = []struct {
Name string
Args []string
File string
}{
{Name: "dmidecode", Args: []string{"-t", "0"}, File: "dmidecode-type0.txt"},
{Name: "dmidecode", Args: []string{"-t", "1"}, File: "dmidecode-type1.txt"},
{Name: "dmidecode", Args: []string{"-t", "2"}, File: "dmidecode-type2.txt"},
{Name: "dmidecode", Args: []string{"-t", "4"}, File: "dmidecode-type4.txt"},
{Name: "dmidecode", Args: []string{"-t", "17"}, File: "dmidecode-type17.txt"},
{Name: "lspci", Args: []string{"-vmm", "-D"}, File: "lspci-vmm.txt"},
{Name: "lspci", Args: []string{"-vvv"}, File: "lspci-vvv.txt"},
{Name: "lscpu", Args: nil, File: "lscpu.txt"},
{Name: "lsblk", Args: []string{"-J", "-d", "-o", "NAME,TYPE,SIZE,SERIAL,MODEL,TRAN,HCTL"}, File: "lsblk.json"},
{Name: "sh", Args: []string{"-c", StorageControllerMapScript}, File: "storage-controllers.txt"},
{Name: "sensors", Args: []string{"-j"}, File: "sensors.json"},
// FRU / Elabel: the identity fields the Export Tools "FRU / Elabel" editor
// reads and rewrites (Product Name / server model, serial, part numbers).
// "fru print 0" pins FRU device 0 to match that editor exactly.
{Name: "ipmitool", Args: []string{"fru", "print", "0"}, File: "ipmitool-fru.txt"},
// BMC identity + LAN config, so a support bundle carries the same context
// the FRU editor shows alongside the elabel.
{Name: "ipmitool", Args: []string{"mc", "info"}, File: "ipmitool-mc-info.txt"},
{Name: "ipmitool", Args: []string{"lan", "print"}, File: "ipmitool-lan-print.txt"},
{Name: "ipmitool", Args: []string{"sdr"}, File: "ipmitool-sdr.txt"},
{Name: "ipmitool", Args: []string{"sensor"}, File: "ipmitool-sensor.txt"},
{Name: "ipmitool", Args: []string{"sel", "list"}, File: "ipmitool-sel.txt"},
{Name: "ipmitool", Args: []string{"sel", "time", "get"}, File: "ipmitool-sel-time.txt"},
{Name: "tpm2_getcap", Args: []string{"properties-fixed"}, File: "tpm-properties-fixed.txt"},
{Name: "tpm2_getcap", Args: []string{"pcrs"}, File: "tpm-pcr-banks.txt"},
{Name: "tpm2_pcrread", File: "tpm-pcr-values.txt"},
{Name: "tpm2_gettestresult", File: "tpm-test-result.txt"},
{Name: "nvme", Args: []string{"list", "-o", "json"}, File: "nvme-list.json"},
{Name: "storcli64", Args: []string{"/call/eall/sall", "show", "all", "J"}, File: "storcli64-drives.json"},
// storcli2 (Tri-Mode controllers, e.g. SAS3808-iMR/9500 series) needs an
// explicit /cN target for drive listing, not a /call wildcard — this
// system-level dump alone (no per-controller loop) is still useful raw
// diagnostics; structured per-drive data is collected separately by
// collectStorcli2Drives in the collector package.
{Name: "storcli2", Args: []string{"show", "all", "J"}, File: "storcli2-show-all.json"},
}
// PCIeNvidiaLinkScript samples each NVIDIA GPU's current/max PCIe link
// speed and width from sysfs. Exported so both the boot-time techdump
// (below) and the on-demand support bundle (app/support_bundle.go, which
// re-samples for freshness at bundle-build time) run the identical script
// instead of two copies that can drift.
const PCIeNvidiaLinkScript = `
for d in /sys/bus/pci/devices/*/; do
vendor=$(cat "$d/vendor" 2>/dev/null)
[ "$vendor" = "0x10de" ] || continue
class=$(cat "$d/class" 2>/dev/null)
case "$class" in
0x030000|0x030200) ;;
*) continue ;;
esac
dev=$(basename "$d")
echo "=== $dev ==="
for f in current_link_speed current_link_width max_link_speed max_link_width; do
printf " %-22s %s\n" "$f" "$(cat "$d/$f" 2>/dev/null)"
done
done
`
// PCIeNvidiaLinkUnderLoadScript re-samples PCIeNvidiaLinkScript's sysfs
// attributes while bee-gpu-burn briefly loads the GPUs. An idle-only
// reading can't tell a real degraded slot/riser from NVIDIA's normal
// idle power-management downclock; this is the load-bearing counterpart
// that lets a reader (human or agent) tell the two apart by comparing
// pcie-nvidia-link.txt against pcie-nvidia-link-under-load.txt. See
// bible-local/decisions/2026-08-24-pcie-gpu-gen1-idle-warning.md.
const PCIeNvidiaLinkUnderLoadScript = `
if ! command -v bee-gpu-burn >/dev/null 2>&1; then
echo "bee-gpu-burn not found; cannot sample PCIe link speed under load"
exit 0
fi
bee-gpu-burn --seconds 8 --size-mb 64 >/tmp/bee-pcie-load-burn.log 2>&1 &
burn_pid=$!
sleep 3
` + PCIeNvidiaLinkScript + `
wait "$burn_pid" 2>/dev/null || true
rm -f /tmp/bee-pcie-load-burn.log
`
// StorageControllerMapScript walks /sys/block to record, for every real
// disk, the PCI function of the controller it hangs off and its SCSI HCTL
// address. Consumed by webui's /topo page to parent each disk under its
// actual storage controller (SATA/AHCI, SAS HBA, RAID) node in the topology
// tree instead of a synthetic catch-all branch. Output is one
// "name hctl=<h:c:t:l> ctrl=<dddd:bb:dd.f>" line per disk; hctl is empty for
// NVMe (which is its own PCIe endpoint).
const StorageControllerMapScript = `
for dev in /sys/block/*; do
n=$(basename "$dev")
case "$n" in loop*|ram*|zram*|sr*|md*|dm-*|nbd*|fd*) continue;; esac
[ -e "$dev/device" ] || continue
real=$(readlink -f "$dev/device") || continue
ctrl=""; hctl=""; seen_pci=0
oldIFS=$IFS; IFS=/
for seg in $real; do
case "$seg" in
pci[0-9]*:[0-9]*) seen_pci=1 ;;
[0-9a-f][0-9a-f][0-9a-f][0-9a-f]:[0-9a-f][0-9a-f]:[0-9a-f][0-9a-f].[0-9a-f]) [ "$seen_pci" = 1 ] && ctrl=$seg ;;
[0-9]*:[0-9]*:[0-9]*:[0-9]*) hctl=$seg ;;
*) : ;;
esac
done
IFS=$oldIFS
echo "$n hctl=$hctl ctrl=$ctrl"
done
`
// KernelAERNvidiaScript filters dmesg for PCIe AER, NVRM, and Xid lines —
// cheap (dmesg is already in memory) and the fastest way to tell a real
// PCIe/GPU hardware fault from power-management noise.
const KernelAERNvidiaScript = `
if command -v dmesg >/dev/null 2>&1; then
dmesg | grep -iE 'AER|NVRM|Xid|pcieport|nvidia' || echo "no AER/NVRM/Xid kernel messages found"
else
echo "dmesg not found"
fi
`
var techDumpNvidiaCommands = []struct {
Name string
Args []string
File string
}{
{Name: "nvidia-smi", Args: []string{"-q"}, File: "nvidia-smi-q.txt"},
{Name: "nvidia-smi", Args: []string{"--query-gpu=index,pci.bus_id,serial,vbios_version,temperature.gpu,power.draw,ecc.errors.uncorrected.aggregate.total,ecc.errors.corrected.aggregate.total,clocks_throttle_reasons.hw_slowdown", "--format=csv,noheader,nounits"}, File: "nvidia-smi-query.csv"},
{Name: "nvidia-smi", Args: []string{"conf-compute", "-q"}, File: "nvidia-smi-conf-compute-q.txt"},
// Consumed by webui's /topo page (GPU-GPU NVLink adjacency and per-link
// status/errors) so that page can render from this persisted dump instead
// of shelling out to nvidia-smi on every HTTP request.
{Name: "nvidia-smi", Args: []string{"topo", "-m"}, File: "nvidia-smi-topo.txt"},
{Name: "nvidia-smi", Args: []string{"nvlink", "-s"}, File: "nvidia-smi-nvlink-status.txt"},
{Name: "nvidia-smi", Args: []string{"nvlink", "-e"}, File: "nvidia-smi-nvlink-errors.txt"},
{Name: "sh", Args: []string{"-c", PCIeNvidiaLinkScript}, File: "pcie-nvidia-link.txt"},
{Name: "sh", Args: []string{"-c", PCIeNvidiaLinkUnderLoadScript}, File: "pcie-nvidia-link-under-load.txt"},
{Name: "sh", Args: []string{"-c", KernelAERNvidiaScript}, File: "kernel-aer-nvidia.txt"},
}
type lsblkDumpRoot struct {
Blockdevices []struct {
Name string `json:"name"`
Type string `json:"type"`
Tran string `json:"tran"`
} `json:"blockdevices"`
}
type nvmeDumpRoot struct {
Devices []struct {
DevicePath string `json:"DevicePath"`
} `json:"Devices"`
}
func (s *System) CaptureTechnicalDump(baseDir string) error {
if err := os.MkdirAll(baseDir, 0755); err != nil {
return err
}
for _, cmd := range techDumpFixedCommands {
writeCommandDump(filepath.Join(baseDir, cmd.File), cmd.Name, cmd.Args...)
}
switch s.DetectGPUVendor() {
case "nvidia":
for _, cmd := range techDumpNvidiaCommands {
writeCommandDump(filepath.Join(baseDir, cmd.File), cmd.Name, cmd.Args...)
}
case "amd":
writeROCmSMIDump(filepath.Join(baseDir, "rocm-smi.txt"))
writeROCmSMIDump(filepath.Join(baseDir, "rocm-smi-showallinfo.txt"), "--showallinfo")
}
for _, dev := range lsblkDumpDevices(filepath.Join(baseDir, "lsblk.json")) {
writeCommandDump(filepath.Join(baseDir, "smartctl-"+sanitizeDumpName(dev)+".json"), "smartctl", "-j", "-a", "/dev/"+dev)
}
for _, dev := range nvmeDumpDevices(filepath.Join(baseDir, "nvme-list.json")) {
writeCommandDump(filepath.Join(baseDir, "nvme-id-ctrl-"+sanitizeDumpName(dev)+".json"), "nvme", "id-ctrl", dev, "-o", "json")
writeCommandDump(filepath.Join(baseDir, "nvme-smart-log-"+sanitizeDumpName(dev)+".json"), "nvme", "smart-log", dev, "-o", "json")
}
return nil
}
func writeCommandDump(path, name string, args ...string) {
out, err := exec.Command(name, args...).CombinedOutput()
if err != nil && len(out) == 0 {
return
}
_ = os.WriteFile(path, out, 0644)
}
func writeROCmSMIDump(path string, args ...string) {
out, err := runROCmSMI(args...)
if err != nil && len(out) == 0 {
return
}
_ = os.WriteFile(path, out, 0644)
}
func lsblkDumpDevices(path string) []string {
raw, err := os.ReadFile(path)
if err != nil {
return nil
}
var root lsblkDumpRoot
if err := json.Unmarshal(raw, &root); err != nil {
return nil
}
var devices []string
for _, dev := range root.Blockdevices {
if strings.EqualFold(strings.TrimSpace(dev.Tran), "usb") {
continue
}
if dev.Type == "disk" && strings.TrimSpace(dev.Name) != "" {
devices = append(devices, strings.TrimSpace(dev.Name))
}
}
sort.Strings(devices)
return devices
}
func nvmeDumpDevices(path string) []string {
raw, err := os.ReadFile(path)
if err != nil {
return nil
}
var root nvmeDumpRoot
if err := json.Unmarshal(raw, &root); err != nil {
return nil
}
seen := map[string]bool{}
var devices []string
for _, dev := range root.Devices {
name := strings.TrimSpace(dev.DevicePath)
if name == "" || seen[name] {
continue
}
seen[name] = true
devices = append(devices, name)
}
sort.Strings(devices)
return devices
}
func sanitizeDumpName(value string) string {
value = strings.TrimSpace(value)
value = strings.TrimPrefix(value, "/dev/")
value = strings.ReplaceAll(value, "/", "_")
if value == "" {
return "unknown"
}
return value
}