The fan-ceiling check, the webui metrics collector (every 5s) and the PSU
health poller each shelled out to ipmitool independently. The BMC's KCS
interface serializes those calls anyway, so under load the concurrent
`ipmitool sdr`/`dcmi power reading` invocations just queued behind each
other — that's what produced "IPMI slow" backoff during a fan-ceiling run in
a blackbox dump, while the dashboard looked fine only because it was reading
its own, separately-stale data from a different ipmitool call.
hw_telemetry.go is now the sole recurring poller (fan RPM, temperature, PSU
power/status, DCMI system power), with the adaptive 1s-30s backoff that used
to be duplicated inside the fan check. Every hot-path consumer reads the
shared cache (hwSnapshot / platform.HardwareSDRSnapshot) instead of calling
ipmitool itself.
Co-Authored-By: Claude Sonnet 5 <noreply@anthropic.com>
bee_layer_classify only ever tracked regular files and symlinks
(`find ... -type f -o -type l`), so any directory that is empty at
build time — like /var/log/nvidia-dcgm, correctly created and chowned
by the datacenter-gpu-manager postinst — was silently dropped from
every layer's rsync --files-from list and never reached the built
ISO. This is why bbc6fb1's 78d1b9b follow-up (seeding a marker file
just for that one path) kept the directory alive: it was a targeted
workaround for a general gap in the classifier, not a fix of it.
Replace that workaround with the general mechanism: classify also
walks every directory, computes the subset that is empty all the way
down (no file or symlink anywhere in its subtree — a directory that
does hold files needs no entry, rsync already recreates it as an
implied parent), and assigns each one to a layer via the same
dpkg-ownership / injected-rule precedence used for files. Add an
injected rule routing /var/log/nvidia-dcgm to 20-nvidia-platform,
alongside the DCGM binaries that actually use it, instead of letting
it fall through to base by default.
bee_layer_build folds each layer's empty-dir list into the same
rsync --files-from call; recursion into a directory that is
by-construction empty copies nothing extra. Revert the 9000/9999 hook
changes from 78d1b9b now that they're redundant, and cover the new
path with test-squashfs-layers.sh (ruled, unruled, and nested-empty
directories, asserted present in the merged rootfs after a real
mksquashfs/unsquashfs round-trip).
Co-Authored-By: Claude Sonnet 5 <noreply@anthropic.com>
bbc6fb1 chowned the directory correctly but it stayed empty at build
time, and bee_layer_classify (squashfs-layers.sh) only tracks regular
files and symlinks via `find ... -type f -o -type l` — an empty
directory is silently dropped from every layer's rsync --files-from
list and never reaches the built ISO. dcgmi diag's deployment check
still failed with DCGM_FR_FILE_CREATE_PERMISSIONS after rebuilding on
top of that fix because the directory simply didn't exist at boot.
Seed /var/log/nvidia-dcgm/.keep so the directory rides along the
classifier as an implied parent (rsync -a preserves its ownership),
and stop 9999-slim's log sweep from deleting that marker before the
classifier ever sees it.
Co-Authored-By: Claude Sonnet 5 <noreply@anthropic.com>
nv-hostengine drops privileges to --service-account nvidia-dcgm for all
file I/O and writes diagnostics to DCGM_HOME_DIR (/var/log/nvidia-dcgm,
per the packaged unit's Environment=). The package postinst doesn't
reliably create/own this directory inside a live-build chroot, so
dcgmi diag's software deployment check fails with
DCGM_FR_FILE_CREATE_PERMISSIONS at boot even though every GPU passes
the actual hardware tests.
Co-Authored-By: Claude Sonnet 5 <noreply@anthropic.com>
Booting via BMC virtual CD reads the ~2.8 GB filesystem squashfs
sequentially during the live-boot toram copy; a mid-read drop of the
redirected medium loses the whole copy and fails the boot (v14). Split
the rootfs into self-contained semantic layers so a retry re-reads at
most one ~500-700 MiB layer, not everything. This is a resilience /
reduced-re-read mechanism, not a fix for the virtual-media instability.
NVIDIA variants now ship 7 layers (00-base, 05-firmware, 08-desktop,
10-nvidia-driver, 20-nvidia-platform, 30-nvidia-cuda-libs,
40-nvidia-dcgm-cuda) plus an explicit live/filesystem.module that fixes
their OverlayFS order; amd/nogpu keep a single squashfs.
- lib/squashfs-layers.sh: deterministic classifier (dpkg file ownership
plus explicit rules for build.sh-injected files, never a path
substring), per-layer mksquashfs, 800 MiB hard ceiling, unsquashfs -s
plus strict extraction of every layer, merged-rootfs bootability check.
- build.sh: split the monolith after the full lb build, verify and merge,
write the module file, delete the monolith only then; abort before ISO
assembly on any failure. Runs the builder test suites up front.
- fast-path: force a full build for a multi-layer medium;
fast_path_repack_squashfs hard-refuses (it would drop layers).
- iso-validation.sh: validate_iso_squashfs_layers (module vs layer set
match, size ceiling, no lone giant squashfs) and
validate_iso_media_integrity (xorriso -check_media).
- bee-install: honour filesystem.module order, abort on any layer failure.
- 9013-toram-retry: record the real rsync exit code (it printed a false
rc=0) and correct the "resumes the tail" comment (rsync without
--partial keeps only fully-copied layers). No unsafe partial resume.
- tests: test-squashfs-layers.sh plus a multi-layer guard in
test-build-libs.sh; both run at the top of every build.
- docs: bible-local architecture and decision, iso/README, iso-build-rules.
Verified by a full nvidia build: 7 layers 622/199/256/466/37/567/562 MiB,
every validator passes, xorriso -check_media good, merged rootfs bootable.
Co-Authored-By: Claude Sonnet 5 <noreply@anthropic.com>
The passive collector records PSU draw at idle too, so right after boot
the "observed peak" is just idle wattage and a load % off it is
meaningless. Require the observed peak to sit >=25% above current draw
before using it as a load scale; until a real full-load run bumps it,
show plain watts.
Co-Authored-By: Claude Sonnet 5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_019VHG21rgTUiR1G3qFHTVmN
Extract the fan peak-tracking into observedPeakStore (observe max under
load, hold >= minHold to reject spikes, round, persist JSON) and add a
second instance for PSU draw (psu-observation.json, keyed by PSU
ordinal). Fed from samplePSUPower like fans are from sampleFanSpeeds, so
any full-load run refines it — the Fan Ceiling Check (which also samples
PSU power at a slow cadence off its loop and writes psu_<i>_peak_w), a
burn, thermal cycling, and the 5s web metrics collector.
/topo PSU cards now scale the load fill by wattage_w when the BMC
reports it, else by the observed peak draw — marked "~N% load". This
MSI stand's BMC gives only instantaneous input power, so the observed
peak is the only capacity figure available.
Fan behaviour is unchanged (tests exercise updateFanObservation /
estimateFanDutyCyclePctFromObservation / ResolveFanMaxRPM through the
new store).
Co-Authored-By: Claude Sonnet 5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_019VHG21rgTUiR1G3qFHTVmN
Same idea as the fan duty-cycle fill: a bar rising from the bottom of
each PSU card for draw / nameplate rating, live-updated on the shared
5s /api/metrics/latest poll. Drawn only when the rating (wattage_w) is
known — a raw wattage with nothing to scale against is not a load
figure, so BMCs that report only input power (e.g. this MSI stand) keep
showing the plain watts. Detail line becomes "<v> V · <draw> / <rating> W
· <n>% load" when both are present.
Co-Authored-By: Claude Sonnet 5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_019VHG21rgTUiR1G3qFHTVmN
Each PSU is its own card, coloured by its own status — a failed unit
goes red on its own instead of dragging a single grouped card down —
and shows input voltage + draw (measured output/input, else nameplate
rating). Cards click through to the PSU detail modal and carry data-psu
so the shared topoLiveScript refreshes their wattage from
/api/metrics/latest on the same 5s poll as the fan tiles.
Co-Authored-By: Claude Sonnet 5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_019VHG21rgTUiR1G3qFHTVmN
Each fan tile carries data-fan / data-ceil / data-measured and a small
script polls /api/metrics/latest every 5s — the metrics collector's own
sampling period, served from memory with no extra BMC call — updating
each tile's spin rate, duty fill and tooltip in place. Polling faster
would only re-read identical numbers; sampling the BMC faster would
choke it under load. FanReading gains json tags for the endpoint.
Co-Authored-By: Claude Sonnet 5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_019VHG21rgTUiR1G3qFHTVmN
It is a platform cooling test (CPU + memory always; GPU only as extra
heat when present), not a GPU test — so it belongs with the other
whole-box checks, not in the NVIDIA section. Still Load-page only, via
the new renderLoadOnlySATCard (inverse of renderCheckOnlySATCard).
Co-Authored-By: Claude Sonnet 5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_019VHG21rgTUiR1G3qFHTVmN
- GPU load switches from bee-gpu-burn (compute burn, ~88% TDP) to
dcgmproftester -t 1004 / targeted_power via
resolveBenchmarkPowerLoadCommand — the same engine Power/Thermal Fit
uses and the hottest sustained NVIDIA load we have, so fans are
actually pushed toward their ceiling.
- Sample loop is now IPMI-hang-proof: every ipmitool read is time-boxed
in an abandonable goroutine, and the poll interval backs off
geometrically (1s→30s) when reads are slow, tightening again on
recovery. A plateau is only trusted while telemetry is healthy;
degraded runs ride out to MaxLoadSec. Summary gains fan_samples /
telemetry_degraded. Drops the per-second nvidia-smi+power+cpu-temp
sampling from the hot loop.
- Dead code removed: FanStressRow, GPUStressMetric, sampleFanStressRow,
sampleGPUStressMetrics, WriteFanStressCSV/WriteFanSensorsCSV,
analyzeMaxTemp, sampleSystemPowerResolved.
Topology fan tiles:
- size encodes the fan's ceiling RPM (its class), not current speed;
coloured fill rising from the bottom encodes live duty cycle
(current / ceiling), shown only when the ceiling was measured.
- glyph spin rate now maps absolute RPM into a human-perceptible band
(fanSpinPeriodSec: 2.2s/turn at <=1000 RPM, 0.35s at >=13000).
- the "N fans · N OK · tile size ∝ …" caption line is gone.
Co-Authored-By: Claude Sonnet 5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_019VHG21rgTUiR1G3qFHTVmN
Repurpose the previously-unwired RunFanStressTest into RunFanCheck, a
Load-tier SAT test that drives stressapptest (CPU+memory) and, when a GPU
is present, a GPU burn to 100% simultaneously, then watches every fan
until none has climbed for ~60s. The observed peak RPM per fan is the
"ceiling"; it is persisted through the existing fan-observation store.
MSI G4201 / AMI MegaRAC exposes no host-side fan force (every OEM IPMI
command returns 0xc1; Redfish Thermal is GET-only), so load-driven ramp
is the closest safe equivalent. See
bible-local/decisions/2026-09-04-fan-ceiling-check.md.
- platform.ResolveFanMaxRPM: per-fan max with fallback (persisted peak ->
peer peak -> current RPM), resolved in platform, not the view.
- platform.ErrTestNotApplicable: no load source or no fan sensors ->
task lands as cancelled ("not applicable"), never failed, so an
engineer never sees a false red. executeTaskWithOptions maps the
sentinel; finalizeTaskForResult honours a pre-set TaskCancelled.
- Verdict FAIL only for a fan at 0 RPM / IPMI cr-nr under load.
- /topo: one small spinning square per fan, sized by RPM / resolved max,
clickable through to a new "fan" component-detail type; per-fan status
recorded to the component-status DB from the fan SAT summary.
- Wiring: /api/sat/fan/run route, "fan" task target, Load-page card,
stress-mode Run All.
Co-Authored-By: Claude Sonnet 5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_019VHG21rgTUiR1G3qFHTVmN
Every GPU-selection picker (Load/SAT, Burn, Benchmark) now renders the
card serial: "GPU N — <model> · <mem> MiB · sn: <serial>". The serial is
monospace and the digits that differ across the listed GPUs (common
prefix/suffix stripped) are emphasised so operators can tell cards apart.
Row markup was duplicated across three pages (and twice within
page_validate.go). Consolidated into a single module,
internal/webui/gpu_picker.go: beeGpuPicker.render({...}) builds every row;
gpuPickerCSS/gpuPickerJS are injected once by layoutHead/renderPage. Pages
keep their own selection-note text and multi-GPU toggles but no longer
hand-build <label> markup.
ListNvidiaGPUs() adds the serial via nvidia-smi --query-gpu=...,serial;
N/A is normalised to empty. Serial flows to the client unchanged through
the existing /api/gpu/nvidia JSON response.
Co-Authored-By: Claude Sonnet 5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01AudE3Q2nd9kxxVuxPKcTho
Every sample was stamped with time.Now(), so a timezone switch or NTP
step punched a multi-hour gap into the series: old points collapsed to
the left edge, new points bunched at the right, joined by one diagonal.
Stamp rows from a monotonic seqClock instead — seeded once from the wall
clock (or the newest persisted row) and thereafter advanced only by the
monotonic elapsed time between writes. Rebase Downsample/Prune on the
newest sample rather than time.Now() so a clock step just before the
hourly compaction can't drop fresh data.
Co-Authored-By: Claude Sonnet 5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01GofKhuF9xQHaz3UFfncR6D
The NVIDIA GSP firmware was staged into the overlay at a bare
lib/firmware/nvidia/<ver>/. On a merged-usr Debian root /lib is a symlink
to usr/lib, so the fast-path repack's `rsync -a` (overlay stage -> the
unsquashfs'd tree) replaced that symlink with a plain directory holding
only the firmware. Everything else reachable only through /lib
(/lib/systemd/systemd, /lib/x86_64-linux-gnu/ld-linux + libc, ...) was
orphaned. The squashfs still packed and mounted, but boot panicked:
run-init: can't execute '/sbin/init': No such file or directory
run-init: can't execute '/bin/sh': No such file or directory
Kernel panic - not syncing: Attempted to kill init
Full `lb build` was unaffected (live-build copies includes.chroot with
cp -a, which follows the /lib symlink), so only fast-path ISOs were bad.
Three fixes:
- build.sh: stage GSP firmware under usr/lib/firmware/nvidia/<ver>/, the
canonical merged-usr path. Changing the overlay path also makes
overlay_paths_were_removed() force one full build on the next run.
- fast-path.sh: add `rsync --keep-dirlinks` so a real directory in the
overlay stage can never again replace a symlink-to-directory in the
root. Verified: firmware lands in usr/lib/firmware, /lib stays a symlink.
- iso-validation.sh: new validate_iso_rootfs_layout, run for every variant
on both build paths. Fails the build if the squashfs has a plain-dir
/bin|/sbin|/lib|/lib64, or if /usr/sbin/init is present without a
resolvable /usr/lib/systemd/systemd and /lib symlink. Verified it flags
the broken v14.02-1-g642e686 ISO and passes a correct layout.
Co-Authored-By: Claude Sonnet 5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01H2LLuid8PFhBqBPcxXxkQU
On hosts where the boot medium is BMC/IPMI virtual media, the ~2.8 GB
squashfs read often drops mid-transfer: rsync dies with "Input/output
error (5)", every file "has vanished", and live-boot moves the partial
RAM copy over the medium, ending the boot with "No supported filesystem
images found at /live".
Add hook 9013-toram-retry, which patches live-boot's 9990-toram-todisk.sh
so the whole-medium copy runs in a retry loop: up to 8 attempts with a
geometrically growing pause (15s -> 900s cap), unmounting/waiting/remounting
the medium between tries and honouring rsync's exit code (upstream ignores
it). rsync resumes from where it stopped, so a retry needing only the tail
finishes fast.
Verified against live-boot 1:20230131+deb12u1: substitution applies,
sh -n is clean, hook is idempotent.
Co-Authored-By: Claude Sonnet 5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_018JA6Cj84yxUfk8N3ppw6mr
needs_full_build() decided the fast path was safe by hashing only config
inputs (VERSIONS, package lists, hooks, archives, auto/config, Dockerfile).
It never hashed the build logic itself, so a change to build.sh or
lib/fast-path.sh counted as a "light" file and the next build silently
reused a squashfs produced by the old code. The merged-usr /lib fix in the
previous commit only forced a full rebuild by accident (the overlay
manifest saw firmware move from lib/ to usr/lib/).
hash_heavy_config now covers every *.sh under iso/builder (build.sh, the
build-*.sh helpers, lib/*.sh) plus auto/. A change to build logic is now
as heavy as a package-list change. config/bootloaders stays excluded (the
fast path regenerates the outer ISO layer from it every time). Hash is
deterministic (LC_ALL=C sort).
Co-Authored-By: Claude Sonnet 5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01H2LLuid8PFhBqBPcxXxkQU
The techdump — the only place the IPMI FRU / Elabel identity (Product Name
= server model, serials, part numbers) is recorded — only ran under LiveCD.
Run it on every audit so `bee audit` on an installed host captures it too.
Also add `ipmitool mc info` and `ipmitool lan print` to the techdump, and
pin `ipmitool fru print 0` to FRU device 0 to match the Export Tools
"FRU / Elabel" editor exactly.
Co-Authored-By: Claude Sonnet 5 <noreply@anthropic.com>
Rework the /topo diagram from side-by-side stacked cards into one tall
vertical bar per CPU socket with everything attached to it branching off
sideways (socket 0 left/branches right, socket 1 right/branches left).
Disks are now parented under the storage controller they physically hang
off (SATA/AHCI, SAS HBA, RAID) — itself a NUMA-affine PCIe device under one
socket — instead of a synthetic catch-all node. The disk->controller link
is read from a new storage-controllers.txt techdump
(platform.StorageControllerMapScript, a /sys/block walk); disks with no
resolvable controller fall back to an "Other" bar. No board/root node.
Co-Authored-By: Claude Sonnet 5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SYjrG6bVmeG1Z2Wmc8kg3o
The bundle README is the bootstrap for an agent that knows nothing about
the layout; it listed neither the pcie-link (whole-bus link-retrain) nor
the tpm (read-only) SAT target, so a reader had no pointer to
tasks/bee-sat/pcie-link-* / tpm-* or their summary keys. Add a Fastest-
answers entry for each, refresh the component-status key examples, and add
a Signatures line for the bridge-side link-retrain false positive (bridge
DEGRADED at before==after==max while its downstream endpoint reads OK =
link at the device's native max, not a fault).
Co-Authored-By: Claude Sonnet 5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01Mx6AvuXcJNT7jx3jjWw4hc
The downstream-capability adjustment lowered f.MaxSpeed/f.MaxWidth to the
rate the endpoint supports, but the Degraded verdict still compared the
retrained speed against the stale local maxSpeed holding the bridge's own
uncapped capability. A Gen5 root port feeding a Gen4 HBA (or a Gen2 NIC)
was flagged DEGRADED even though the link ran at the fastest rate the pair
supports, failing the PCIe link check on healthy hardware.
Keep the local maxSpeed in sync with the peer-capped f.MaxSpeed so both
the pre-retrain and post-retrain verdicts use the real target.
Co-Authored-By: Claude Sonnet 5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01Mx6AvuXcJNT7jx3jjWw4hc
pcie-link's retrain check compared post-retrain speed against a port's
max capability without checking whether anything was actually seated
downstream. A switch downstream port with no card plugged in retrains
to zero lanes but still reports a reset-state speed, so it was
misreported as "retrained to Gen1, capable of Gen5" — indistinguishable
from a real degraded link.
Now a port that was already empty before the retrain is skipped (same
treatment as a disabled device: legitimately unpopulated slots are
common and shouldn't fail the check), while a device that answered
before the retrain and disappeared right after it still fails, with an
honest "no device detected downstream" message instead of a fabricated
speed reading.
Co-Authored-By: Claude Sonnet 5 <noreply@anthropic.com>
mirror.mephi.ru was timing out during lb binary_rootfs. Default to
deb.debian.org (Fastly-backed, geo-balanced) and allow overriding via
--mirror on build-in-container.sh/build.sh, or BEE_MIRROR in auto/config.
Co-Authored-By: Claude Sonnet 5 <noreply@anthropic.com>
pcie-nvidia-link.txt, pcie-nvidia-link-under-load.txt, and
kernel-aer-nvidia.txt only ever lived in supportBundleCommands, which
exclusively runs inside the on-demand "Download Support Bundle" web UI
action. The blackbox USB auto-sync worker never calls that function -
it only mirrors whatever CaptureTechnicalDump already wrote into the
live export tree at boot. So these three files were structurally
unreachable from a blackbox pull no matter how fresh the build was;
earlier analysis of a real blackbox misattributed their absence to
build/version drift instead.
Move the underlying scripts into shared exported constants
(platform.PCIeNvidiaLinkScript, PCIeNvidiaLinkUnderLoadScript,
KernelAERNvidiaScript) and add them to techDumpNvidiaCommands, so
CaptureTechnicalDump captures all three once at boot (bee-audit is
oneshot, so the ~8s bee-gpu-burn cost for the under-load sample is a
one-time boot cost, not a per-sync-cycle one) alongside the existing
nvidia-smi-* dumps. supportBundleCommands still re-runs the same
scripts on demand for a fresher sample - that's intentional, not a
duplicate to clean up.
Co-Authored-By: Claude Sonnet 5 <noreply@anthropic.com>
NVIDIA GPUs deliberately downclock PCIe to Gen1 at idle for power
saving, and applyPCIeLinkSpeedWarning fired on every idle collector
pass regardless - since component-status DB records never downgrade
(Record() only ever raises severity), one boot-time idle sample
permanently pinned pcie:gpu:nvidia to Warning for the rest of the
session even after every load-bearing GPU SAT test passed clean. Two
prior fixes (nvidia-smi-sourced link speed, pcie_aspm=off boot flag)
didn't hold up against this hardware/driver combination - see
bible-local/decisions/2026-08-24-pcie-gpu-gen1-idle-warning.md for the
full history.
Rather than add a downgrade path, stop writing an unverified status in
the first place: parseLspciDevice no longer calls
applyPCIeLinkSpeedWarning on the idle path. LinkSpeed/MaxLinkSpeed stay
populated as plain descriptive fields; only a verified-under-load
caller may now turn them into a status verdict.
Two new SAT targets provide that verified signal:
- pcie-link (platform/pcie_link_check.go): forces every enabled PCIe
device - not just GPUs - to retrain via the PCIe spec's Link Control
"Retrain Link" bit, then compares the negotiated speed against the
device's max. Covers NICs/HBAs/switches that have no bee-gpu-burn
equivalent load tool. Classifies by PCI class code + vendor ID, not
name substrings. Routes gpu_nvidia/gpu_amd/other sub-verdicts into
their own component-status keys so a degraded NIC never reads as a
GPU fault.
- nvidia-pcie-bandwidth (platform/nvidia_pcie_bandwidth.go): drives
real host<->device traffic via dcgmi diag -r nvbandwidth and
resamples link speed immediately after, independent of nvbandwidth's
own pass/fail.
Both wired into the task queue/webui the same way as nvidia-config
(routes, dispatch, priority, Validate page cards, Run All Check SAT).
Co-Authored-By: Claude Sonnet 5 <noreply@anthropic.com>
`ipmitool fru edit` frequently exits non-zero after a field resize
(shrinking/growing a string shifts every later offset in the FRU
record) even though the write itself landed correctly on the BMC -
the failure is in ipmitool's own post-write re-parse, not the write.
bee was treating that exit code as authoritative and marking the task
failed even when the field was actually written.
runIPMIFRUWriteTask now re-reads the FRU on a non-zero exit and
compares the target field's actual value before deciding the task
failed, logging which path it took either way.
Co-Authored-By: Claude Sonnet 5 <noreply@anthropic.com>
A CPU that had thermally throttled (sysfs thermal_throttle counter >
0) still reported status "OK" everywhere: dmidecode-derived CPU status
only distinguishes populated/enabled/disabled and never looked at the
throttle flag the collector already recorded next to it, and neither
SAT path meant to catch this actually could:
- The routine "cpu" SAT pack (RunCPUAcceptancePack) only checked
lscpu/sensors/stress-ng exit codes — stress-ng exits 0 whether or
not the CPU throttled while running it, so an 89°C/throttled CPU
right after a "successful" run still showed cpu:all as OK in
component-status.json.
- The more thorough platform-stress test already detected throttling
and fan-spindown correctly, but wrote its verdict as "Overall: FAIL
— ..." with no "=", which parseSATKV can't parse — so even a real
detected throttle event never reached the component-status DB.
Fixes:
- cpu_telemetry.go: escalate a CPU's status to Warning (only-escalate,
same severity ranking already used elsewhere) when Throttled is set.
- sat.go: add a before/after thermal-throttle-counter check job around
the "cpu" pack's stress-ng run, so a throttle event during the run
fails that job and (via the existing FAILED->Warning DB mapping)
flips cpu:all to Warning.
- platform_stress.go: emit a machine-readable overall_status= line
alongside the human-readable verdict so platform-stress results
actually reach ApplySATResultToDB.
Co-Authored-By: Claude Sonnet 5 <noreply@anthropic.com>
dmesgSeverity classified a kernel log line as Critical via plain
strings.Contains, without word boundaries, so common words that merely
contain a keyword as a substring false-positive — "disabled by
default" was flagged Critical because "default" contains "fault"
(de-fault). Found in a support bundle where 140/238 event_logs entries
came back Critical, most of them harmless boot messages (module load
notices, "... is initialized", "disabled by default"), drowning out
genuinely critical entries (Xid, AER, ECC) in the same list.
Switch to the same \b-bounded regexes already used for the capture
patterns above it in this file.
Co-Authored-By: Claude Sonnet 5 <noreply@anthropic.com>
An NVMe SSD passed through a RAID/HBA as /dev/sdX (not /dev/nvmeX) gets
smartctl'd over the SCSI protocol, which reports its model in
scsi_model_name/scsi_vendor/scsi_product instead of the ATA/NVMe
model_name field. smartctlInfo only mapped model_name, so the drive's
model was silently dropped from reanimator.json even though smartctl
ran successfully and the serial number came through fine — caught via
a support bundle where lsblk showed "SSSTC CA6-8D1024" for a drive but
reanimator.json's storage entry had no model at all.
Add scsi_model_name/scsi_vendor/scsi_product to smartctlInfo and fall
back to them, in that order, when model_name is empty.
Co-Authored-By: Claude Sonnet 5 <noreply@anthropic.com>
A wedged GPU (fallen off the bus, needs a physical power-cycle) makes
nvidia-smi/nvidia-bug-report.sh/dcgmi hang indefinitely, so building a
support bundle on such a host never finished and the "Download Support
Bundle" button spun on "Building..." forever with no way to recover
short of restarting the service.
Give every subprocess this file shells out to a bounded context.
nvidia-bug-report.sh gets a longer timeout since it legitimately takes
tens of seconds on multi-GPU boxes even when healthy.
Co-Authored-By: Claude Sonnet 5 <noreply@anthropic.com>
statusSeverity was byte-for-byte duplicated in collector/contract.go and
app/sat_overlay.go (same switch, same comment). Export it as
collector.StatusSeverity and drop the app-package copy.
page_topo.go inlined the same GPU/NIC/RAID class switch as its own
pcieDeviceKind function in one spot — call the function instead.
page_validate.go had its own copy of pages.go's firstNonEmpty (all call
sites already pre-trim their inputs via validateTrimPtr, so the extra
TrimSpace was redundant) — drop the duplicate.
Co-Authored-By: Claude Sonnet 5 <noreply@anthropic.com>
matchesGPUVendor (sat_overlay.go) matched any PCIe DeviceClass containing
the substring "Controller" instead of the actual GPU classes, so a
same-vendor non-GPU device (e.g. an NVIDIA-branded NIC/storage controller)
with a degraded PCIe link surfaced as a pcie:gpu:<vendor> alarm on the
Hardware Summary/webui.
isGPUDevice (app_format.go) had the same bug via a different path: an
"any NVIDIA-vendor device is a GPU" fallback that could inflate the
"GPU: N x <model>" audit summary line with non-GPU companion devices
(NVSwitch/NVLink bridges, etc).
Both now defer to collector.IsGPUClass (exported from the previously
unexported isGPUClass), the canonical exact-match classifier already used
by amdgpu.go — removing the duplicated/incorrect class checks instead of
reimplementing them. Also dedup two more locally-duplicated classifiers
within webui (which doesn't import collector by convention): NIC-class
matching (pages.go/page_topo.go) and GPU-class matching in
page_validate.go now share one copy per package instead of being
reimplemented per file.
Co-Authored-By: Claude Sonnet 5 <noreply@anthropic.com>
buildNvidiaTaskSet only treated ParallelGPUs as a reason to keep all
selected GPUs in one task, so ramp-up (StaggerGPUStart) fell through
to per-model task splitting. When that split left a single GPU in a
task, resolveNvidiaRampPlan silently returned StaggerSeconds=0,
making the ramp-up toggle a no-op.
Co-Authored-By: Claude Sonnet 5 <noreply@anthropic.com>