Michael Chus 47ff1c3796 fix(inspur): detect standard Inspur servers via SystemManufacturer
NF-series storage servers (e.g. NF5280M6) have no GPU/outboard-PCIe
topology, so the previous score gate (topologyScore==0 || boardScore==0
→ return 0) always produced score=0 despite SystemManufacturer="Inspur"
being available. These servers fell into mode=fallback, activating the
AMI profile and probing /Oem/Ami paths that don't exist on the BMC.

Add manufacturer-based detection: SystemManufacturer or
ChassisManufacturer containing "inspur" contributes 60 points —
enough to enter matched mode on its own. GPU servers with full
topology+board signals still score higher as before.

Co-Authored-By: Claude Sonnet 4.6 <noreply@anthropic.com>
2026-06-12 03:58:55 +03:00
2026-02-25 13:31:54 +03:00
2026-03-16 00:20:11 +03:00
2026-03-15 16:35:16 +03:00
2026-03-15 16:35:16 +03:00
2026-03-16 00:20:11 +03:00
2026-03-15 16:35:16 +03:00

LOGPile

Standalone Go application for BMC diagnostics analysis with an embedded web UI.

What it does

  • Parses vendor diagnostic archives into a normalized hardware inventory
  • Collects live BMC data via Redfish
  • Exports normalized data as CSV, raw re-analysis bundles, and Reanimator JSON