Mikhail Chusavitin 4f7b5b826a fix(inspur): fix PSU section regex when PCIE section precedes Network
The PSU regex used "RESTful Network" as its end anchor, but in standard
Inspur component.log layout the PCIE Device section sits between PSU and
Network Adapter. The lazy [\s\S]*? captured across the PCIE error block,
producing invalid JSON and silently dropping all PSU data.

Changed anchor to RESTful (?:PCIE|Network) — matches whichever section
immediately follows PSU in a given archive.

Co-Authored-By: Claude Sonnet 4.6 <noreply@anthropic.com>
2026-05-21 14:21:13 +03:00