Files
mchusandClaude Sonnet 5 74e6bf0578 fix(parser): support Inspur HGX dump_<serial>_<timestamp>/ onekeylog layout
Fixes #20. This onekeylog variant has no devicefrusdr.log at all: FRU/sensors
come from raw ipmitool text output, PCIe/GPU presence has a dedicated
structural snapshot, SEL lives at a different path, and BMC component
failures are logged separately from SEL/IDL.

- Fall back to component/fru.txt (same FRU block format as devicefrusdr.log)
  and component/sensor.txt / sdr.txt (ipmitool sensor list / sdr elist)
  when devicefrusdr.log is absent.
- Parse log/bmc/diagnose/OtrdDiagnoseComponent.json's PCIe Device Info array
  for GPU/PCIe presence and link state, independent of SEL/IDL alarm
  history; flag devices running below their negotiated max link
  speed/width as degraded with a Warning event.
- Fall back to log/sel.csv (same format as selelist.csv) when selelist.csv
  is absent.
- Parse log/bmc/commer-comp/{commerslot,commerhmc,commerswvr,commerswcpld}
  logs (including rotated *.tar.gz.N parts) into failure events, filtering
  known-noisy lines.
- Collapse SEL events duplicated across sources by
  (timestamp, event_type, description).
- Surface a CollectionError when FRU/sensors are still empty after all
  fallbacks, instead of silently returning an empty inventory.
- Fix ParseFRU: a later placeholder "Product Serial : 0" / "Product Part
  Number : NULL" line in the same FRU block (e.g. SCM_FRU) was overwriting
  an already-parsed real Board Serial/Part Number.

Verified against dump_23DB01633_20260727-1359.tar.gz (HGX B200, KR9288-X3):
fru 0→21, sensors 0→303, 8 GPUs present at Gen5 x16 in slots 100-107.

Deferred (not covered by this change): BIOS-change-settings context and
BIOS POST codes from the same layout — see bible-local/10-decisions.md
ADL-048.

Co-Authored-By: Claude Sonnet 5 <noreply@anthropic.com>
2026-07-29 10:05:58 +03:00

48 lines
1.6 KiB
Go

package inspur
import "testing"
func TestParseSensorList(t *testing.T) {
content := []byte(`============
Description:sensor list
Command: ipmitool sensor list
Response:
Inlet_Temp | 21.000 | degrees C | ok | na | na | na | na | 40.000 | na
GPU0_Temp | 29.000 | degrees C | ok | na | na | na | na | 86.000 | na
PSU0_Status | 0x0 | discrete | 0x0180| na | na | na | na | na | na
`)
readings := ParseSensorList(content)
if len(readings) != 3 {
t.Fatalf("expected 3 readings, got %d", len(readings))
}
if readings[0].Name != "Inlet_Temp" || readings[0].Value != 21.0 || readings[0].Unit != "degrees C" {
t.Fatalf("unexpected Inlet_Temp reading: %+v", readings[0])
}
if readings[1].Type != "temperature" {
t.Fatalf("expected temperature type, got %q", readings[1].Type)
}
}
func TestParseSDRElist(t *testing.T) {
content := []byte(`============
Description:sdr elist
Command: ipmitool sdr elist
Response:
Inlet_Temp | 00h | ok | 3.0 | 21 degrees C
GPU0_Temp | 2Ah | ok | 11.0 | 29 degrees C
Event Logging Disabled SEL_Status | 15h | ok | 7.0 | no reading
`)
readings := ParseSDRElist(content)
if len(readings) != 3 {
t.Fatalf("expected 3 readings, got %d", len(readings))
}
if readings[0].Name != "Inlet_Temp" || readings[0].Value != 21 || readings[0].Unit != "degrees C" {
t.Fatalf("unexpected Inlet_Temp reading: %+v", readings[0])
}
if readings[2].RawValue != "" {