BMC readiness after power-on (waitForStablePoweredOnHost): - After initial 1m stabilization, poll BMC inventory readiness before collecting - Ready if MemorySummary.TotalSystemMemoryGiB > 0 OR PCIeDevices.Members non-empty - On failure: wait +60s, retry; on second failure: wait +120s, retry; then warn and proceed - Configurable via LOGPILE_REDFISH_BMC_READY_WAITS (default: 60s,120s) Empty critical collection plan-B retry (EnableEmptyCriticalCollectionRetry): - Hardware inventory collections that returned Members=[] are now re-probed in plan-B - Covers PCIeDevices, NetworkAdapters, Processors, Drives, Storage, EthernetInterfaces - Enabled by default in generic profile (applies to all vendors) Ghost NIC dedup fix (enrichNICsFromNetworkInterfaces): - NetworkInterface entries (e.g. Id=2) that don't match existing NIC slots are now resolved via Links.NetworkAdapter cross-reference to the real Chassis NIC - Prevents duplicate ghost entries (slot=2 "Network Device View") from appearing alongside real NICs (slot="RISER 5 slot 1 (7)") with the same MAC addresses Co-Authored-By: Claude Sonnet 4.6 <noreply@anthropic.com>