Every sample was stamped with time.Now(), so a timezone switch or NTP
step punched a multi-hour gap into the series: old points collapsed to
the left edge, new points bunched at the right, joined by one diagonal.
Stamp rows from a monotonic seqClock instead — seeded once from the wall
clock (or the newest persisted row) and thereafter advanced only by the
monotonic elapsed time between writes. Rebase Downsample/Prune on the
newest sample rather than time.Now() so a clock step just before the
hourly compaction can't drop fresh data.
Co-Authored-By: Claude Sonnet 5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01GofKhuF9xQHaz3UFfncR6D