Mikhail ChusavitinandClaude Sonnet 5 b11018ac5e fix(collector): stop pinning GPU PCIe status on an unverified idle reading
NVIDIA GPUs deliberately downclock PCIe to Gen1 at idle for power
saving, and applyPCIeLinkSpeedWarning fired on every idle collector
pass regardless - since component-status DB records never downgrade
(Record() only ever raises severity), one boot-time idle sample
permanently pinned pcie:gpu:nvidia to Warning for the rest of the
session even after every load-bearing GPU SAT test passed clean. Two
prior fixes (nvidia-smi-sourced link speed, pcie_aspm=off boot flag)
didn't hold up against this hardware/driver combination - see
bible-local/decisions/2026-08-24-pcie-gpu-gen1-idle-warning.md for the
full history.

Rather than add a downgrade path, stop writing an unverified status in
the first place: parseLspciDevice no longer calls
applyPCIeLinkSpeedWarning on the idle path. LinkSpeed/MaxLinkSpeed stay
populated as plain descriptive fields; only a verified-under-load
caller may now turn them into a status verdict.

Two new SAT targets provide that verified signal:

- pcie-link (platform/pcie_link_check.go): forces every enabled PCIe
  device - not just GPUs - to retrain via the PCIe spec's Link Control
  "Retrain Link" bit, then compares the negotiated speed against the
  device's max. Covers NICs/HBAs/switches that have no bee-gpu-burn
  equivalent load tool. Classifies by PCI class code + vendor ID, not
  name substrings. Routes gpu_nvidia/gpu_amd/other sub-verdicts into
  their own component-status keys so a degraded NIC never reads as a
  GPU fault.
- nvidia-pcie-bandwidth (platform/nvidia_pcie_bandwidth.go): drives
  real host<->device traffic via dcgmi diag -r nvbandwidth and
  resamples link speed immediately after, independent of nvbandwidth's
  own pass/fail.

Both wired into the task queue/webui the same way as nvidia-config
(routes, dispatch, priority, Validate page cards, Run All Check SAT).

Co-Authored-By: Claude Sonnet 5 <noreply@anthropic.com>
2026-08-24 18:39:19 +03:00

377 lines
11 KiB
Go

package collector
import (
"bee/audit/internal/schema"
"fmt"
"log/slog"
"os"
"os/exec"
"path/filepath"
"strconv"
"strings"
)
func collectPCIe() []schema.HardwarePCIeDevice {
out, err := exec.Command("lspci", "-vmm", "-D").Output()
if err != nil {
slog.Warn("pcie: lspci failed", "err", err)
return nil
}
devs := parseLspci(string(out))
slog.Info("pcie: collected", "count", len(devs))
return devs
}
func parseLspci(output string) []schema.HardwarePCIeDevice {
// lspci -vmm -D outputs blank-line separated records, each field is "Key:\tValue"
var devs []schema.HardwarePCIeDevice
for _, block := range strings.Split(output, "\n\n") {
block = strings.TrimSpace(block)
if block == "" {
continue
}
fields := map[string]string{}
for _, line := range strings.Split(block, "\n") {
idx := strings.Index(line, ":\t")
if idx < 0 {
continue
}
key := strings.TrimSpace(line[:idx])
val := strings.TrimSpace(line[idx+2:])
fields[key] = val
}
if !shouldIncludePCIeDevice(fields["Class"], fields["Vendor"], fields["Device"]) {
continue
}
dev := parseLspciDevice(fields)
devs = append(devs, dev)
}
return devs
}
func shouldIncludePCIeDevice(class, vendor, device string) bool {
c := strings.ToLower(strings.TrimSpace(class))
v := strings.ToLower(strings.TrimSpace(vendor))
d := strings.ToLower(strings.TrimSpace(device))
if c == "" {
return true
}
// Keep inventory focused on useful replaceable components, not chipset/virtual noise.
excluded := []string{
"host bridge",
"isa bridge",
"pci bridge",
"co-processor",
"performance counter",
"performance counters",
"ram memory",
"system peripheral",
"communication controller",
"signal processing controller",
"usb controller",
"smbus",
"audio device",
"serial bus controller",
"unassigned class",
"non-essential instrumentation",
}
for _, bad := range excluded {
if strings.Contains(c, bad) {
return false
}
}
// Exclude BMC/management virtual VGA adapters — these are firmware video chips,
// not real GPUs, and pollute the GPU inventory (e.g. iBMC, iDRAC, iLO VGA).
if strings.Contains(c, "vga") || strings.Contains(c, "display") || strings.Contains(c, "3d") {
bmcPatterns := []string{
"management system chip",
"management controller",
"ibmc",
"idrac",
"ilo vga",
"aspeed",
"matrox",
}
for _, bad := range bmcPatterns {
if strings.Contains(d, bad) {
return false
}
}
}
if strings.Contains(v, "advanced micro devices") || strings.Contains(v, "[amd]") {
internalAMDPatterns := []string{
"dummy function",
"reserved spp",
"ptdma",
"cryptographic coprocessor pspcpp",
"pspcpp",
}
for _, bad := range internalAMDPatterns {
if strings.Contains(d, bad) {
return false
}
}
}
return true
}
func parseLspciDevice(fields map[string]string) schema.HardwarePCIeDevice {
dev := schema.HardwarePCIeDevice{}
present := true
dev.Present = &present
status := statusOK
dev.Status = &status
// Slot is the BDF: "0000:00:02.0"
bdfStr := fields["Slot"]
if bdfStr != "" {
dev.Slot = &bdfStr
dev.BDF = &bdfStr
// parse vendor_id and device_id from sysfs
vendorID, deviceID := readPCIIDs(bdfStr)
if vendorID != 0 {
dev.VendorID = &vendorID
}
if deviceID != 0 {
dev.DeviceID = &deviceID
}
if numaNode, ok := readPCINumaNode(bdfStr); ok {
dev.NUMANode = &numaNode
} else if numaNode, ok := parsePCINumaNode(fields["NUMANode"]); ok {
dev.NUMANode = &numaNode
}
if group, ok := readPCIIOMMUGroup(bdfStr); ok {
dev.IOMMUGroup = &group
}
if width, ok := readPCIIntAttribute(bdfStr, "current_link_width"); ok {
dev.LinkWidth = &width
}
if width, ok := readPCIIntAttribute(bdfStr, "max_link_width"); ok {
dev.MaxLinkWidth = &width
}
if speed, ok := readPCIStringAttribute(bdfStr, "current_link_speed"); ok {
linkSpeed := normalizePCILinkSpeed(speed)
if linkSpeed != "" {
dev.LinkSpeed = &linkSpeed
}
}
if speed, ok := readPCIStringAttribute(bdfStr, "max_link_speed"); ok {
linkSpeed := normalizePCILinkSpeed(speed)
if linkSpeed != "" {
dev.MaxLinkSpeed = &linkSpeed
}
}
}
if v := fields["Class"]; v != "" {
class := mapPCIeDeviceClass(v)
dev.DeviceClass = &class
}
if v := fields["Vendor"]; v != "" {
dev.Manufacturer = &v
}
if v := fields["Device"]; v != "" {
dev.Model = &v
}
// SVendor/SDevice available but not in schema — skip
// Detect NVLink bridge mezzanine cards (CPU→HGX internal link).
// These are Mellanox x2 devices with no host net interfaces and a DeviceName
// containing "NVLINK". The targeted lspci call is only executed for the small
// number of narrow-link Mellanox cards that pass the cheap pre-filter.
if bdfStr != "" && isNVLinkBridgeCandidate(bdfStr, dev) && confirmNVLinkBridgeDeviceName(bdfStr) {
markNVLinkBridge(&dev)
}
// Deliberately not calling applyPCIeLinkSpeedWarning here: this function
// runs on every idle-time collector pass, and NVIDIA GPUs legitimately
// downclock their PCIe link at idle to save power, making "current <
// max" a false positive most of the time it fires. There's no reliable
// way to downgrade a status once recorded (component-status DB history
// is a one-way transition log, by design — see component_status_db.go),
// so writing an unverified idle reading as Warning meant it stuck for
// the rest of the session even after every load-bearing SAT test passed
// clean. See bible-local/decisions/2026-08-24-pcie-gpu-gen1-idle-warning-unresolved.md.
// applyPCIeLinkSpeedWarning is reserved for a future caller that samples
// link speed while the device is under verified load (a dedicated SAT,
// or a forced link retrain) — only that caller should turn this data
// into a status verdict. LinkSpeed/MaxLinkSpeed above stay populated as
// plain descriptive fields regardless.
return dev
}
// readPCIIOMMUGroup resolves the IOMMU group number for a BDF via the
// iommu_group symlink in sysfs: .../devices/<bdf>/iommu_group -> .../kernel/iommu_groups/<N>
func readPCIIOMMUGroup(bdf string) (int, bool) {
link := "/sys/bus/pci/devices/" + bdf + "/iommu_group"
target, err := os.Readlink(link)
if err != nil {
return 0, false
}
n, err := strconv.Atoi(filepath.Base(target))
if err != nil {
return 0, false
}
return n, true
}
// readPCIIDs reads vendor and device IDs from sysfs for a given BDF.
func readPCIIDs(bdf string) (vendorID, deviceID int) {
base := "/sys/bus/pci/devices/" + bdf
if v, err := readHexFile(base + "/vendor"); err == nil {
vendorID = v
}
if v, err := readHexFile(base + "/device"); err == nil {
deviceID = v
}
return
}
func readHexFile(path string) (int, error) {
out, err := exec.Command("cat", path).Output()
if err != nil {
return 0, err
}
s := strings.TrimSpace(strings.TrimPrefix(string(out), "0x"))
n, err := strconv.ParseInt(s, 16, 64)
return int(n), err
}
func readPCINumaNode(bdf string) (int, bool) {
value, ok := readPCIIntAttribute(bdf, "numa_node")
if !ok || value < 0 {
return 0, false
}
return value, true
}
func parsePCINumaNode(raw string) (int, bool) {
raw = strings.TrimSpace(raw)
if raw == "" {
return 0, false
}
value, err := strconv.Atoi(raw)
if err != nil || value < 0 {
return 0, false
}
return value, true
}
func readPCIIntAttribute(bdf, attribute string) (int, bool) {
out, err := exec.Command("cat", "/sys/bus/pci/devices/"+bdf+"/"+attribute).Output()
if err != nil {
return 0, false
}
value, err := strconv.Atoi(strings.TrimSpace(string(out)))
if err != nil || value < 0 {
return 0, false
}
return value, true
}
func readPCIStringAttribute(bdf, attribute string) (string, bool) {
out, err := exec.Command("cat", "/sys/bus/pci/devices/"+bdf+"/"+attribute).Output()
if err != nil {
return "", false
}
value := strings.TrimSpace(string(out))
if value == "" {
return "", false
}
return value, true
}
// applyPCIeLinkSpeedWarning sets device status when the current PCIe link speed is
// below the device maximum. Regular PCIe slots get Warning; NVLink bridge cards
// get Critical because they are fixed internal connectors that must always train
// to max speed — any downgrade signals a hardware fault.
//
// Disabled devices (sysfs enable==0) are skipped: they carry no data traffic and
// their link state has no operational impact. This covers management endpoints
// (e.g. PCIe switch fabric controllers on HGX baseboards) that the kernel never
// activates but that lspci still reports with link stats.
//
// Not called from the idle collector path (parseLspciDevice) — see the
// comment there. Call this only from a context that just put the device
// under real traffic (a load-bearing SAT, a forced link retrain), so a
// genuine Warning/Critical is never based on an ASPM/power-managed idle
// downclock that a human or SAT would immediately clear anyway.
func applyPCIeLinkSpeedWarning(dev *schema.HardwarePCIeDevice) {
if dev.LinkSpeed == nil || dev.MaxLinkSpeed == nil {
return
}
if pcieLinkSpeedRank(*dev.LinkSpeed) >= pcieLinkSpeedRank(*dev.MaxLinkSpeed) {
return
}
if dev.BDF != nil {
if enabled, ok := readPCIIntAttribute(*dev.BDF, "enable"); ok && enabled == 0 {
return
}
}
desc := fmt.Sprintf("PCIe link speed degraded: running at %s, capable of %s", *dev.LinkSpeed, *dev.MaxLinkSpeed)
dev.ErrorDescription = &desc
isNVLinkBridge := dev.DeviceClass != nil && *dev.DeviceClass == "NVLinkBridge"
if isNVLinkBridge {
crit := statusCritical
dev.Status = &crit
} else {
warn := statusWarning
dev.Status = &warn
}
}
// pcieLinkSpeedRank returns a numeric rank for a normalized Gen string (e.g. "Gen4" → 4).
// Returns 0 for unrecognised values so comparisons fail safe.
func pcieLinkSpeedRank(gen string) int {
switch gen {
case "Gen1":
return 1
case "Gen2":
return 2
case "Gen3":
return 3
case "Gen4":
return 4
case "Gen5":
return 5
case "Gen6":
return 6
default:
return 0
}
}
func normalizePCILinkSpeed(raw string) string {
return NormalizePCILinkSpeed(raw)
}
// NormalizePCILinkSpeed maps a raw sysfs current_link_speed/max_link_speed
// string (e.g. "16.0 GT/s PCIe") to a "GenN" label. Exported for reuse by
// the platform package's PCIe link-retrain SAT, which needs the same
// mapping outside the idle collector path.
func NormalizePCILinkSpeed(raw string) string {
raw = strings.TrimSpace(strings.ToLower(raw))
switch {
case strings.Contains(raw, "2.5"):
return "Gen1"
case strings.Contains(raw, "5.0"):
return "Gen2"
case strings.Contains(raw, "8.0"):
return "Gen3"
case strings.Contains(raw, "16.0"):
return "Gen4"
case strings.Contains(raw, "32.0"):
return "Gen5"
case strings.Contains(raw, "64.0"):
return "Gen6"
default:
return ""
}
}