Michael Chus a714c45f10 fix(metrics): parse rocm-smi CSV by header keywords, not column position
MI250X outputs 7 temperature columns before power/use%; positional parsing
read junction temp (~40°C) as GPU utilisation. Switch to header-based
colIdx() lookup so the correct fields are read regardless of column order