If you are an AI agent that just listed or was pointed at this directory: read this file before opening any other file in it. It tells you what's here and exactly where to look, so you don't burn time grepping through random logs to answer something this file already answers directly.

You are looking at a diagnostic export from bee (BEE-SP), a hardware audit / acceptance-testing / burn-in tool for GPU servers. It runs on the server itself (as a live-CD or an installed service) and produces this export by: collecting a full hardware inventory, running SAT (System Acceptance Test) checks against CPU/memory/storage/GPU/RAID, capturing raw diagnostic command output, and logging its own systemd services.

The bundle is organized around what kind of thing each file is, not which bee component happened to produce it:

  • export/ — raw, vendor-native tool output, grouped by physical device type. Nothing in here needs bee context to read; a NIC vendor can be handed export/network/ and it means the same thing it would from any other collector. Also holds reanimator.json, a ready-to-ingest hardware snapshot.
  • status/computed diagnosis (component health verdicts, runtime status, metrics history), not raw tool output and not a task log.
  • tasks/ — bee's own bookkeeping: full per-run logs, orchestration state, service logs. Expect duplication with export/ here (e.g. a storage SAT run's narrative disk report repeats data already in export/storage/) — that's intentional, this is the "show your work" tier.
  • livecd/ — only relevant to this particular live-boot/kiosk session (GUI stack, DHCP-assigned IPs, kernel ring buffer for this boot). Not hardware facts — ignore this entirely when troubleshooting the physical machine.

Fastest answers to common questions

  • "What hardware is in this server?"export/reanimator.json. The master inventory: board, firmware, CPUs, memory, storage, PCIe devices (GPUs/NICs/RAID controllers), power supplies, sensors, event logs. Every component has a status field (OK/Warning/Critical/Unknown). Same document a POST /ingest/hardware to Reanimator expects (see bible-local/docs/hardware-ingest-contract.md in the bee repo).
  • "Did the acceptance tests pass?" → grep overall_status= across every tasks/bee-sat/*/summary.txt. That key is always present and is the fastest single-line verdict for that run (OK, FAILED, PARTIAL, or UNSUPPORTED).
  • "What's the current rolled-up health per component?"status/component-status.json. One record per component key (e.g. pcie:gpu:nvidia, cpu:all, psu:all), each with a status and a history array. This is what feeds reanimator.json's status fields — it's the source, not a duplicate. The history is a transition log, not a per-check journal — a component whose status never changed only has one entry, even if it was checked hundreds of times. A gap in timestamps does not mean it stopped being monitored.
  • "Is a specific bee service healthy, or did it crash/restart-loop?"tasks/_services/<service>.status.txt (current systemctl status) and tasks/_services/<service>.journal.log (journalctl -u <service> for that service's window). tasks/_services/combined.journal.log has everything, chronological, if you need cross-service correlation. NVIDIA DCGM/fabric-manager daemon status lives in export/gpu/ instead (see below); the display stack's lives in livecd/gui/.
  • "What's the RAID/drive state?"export/storage/storcli64-drives.json and storcli2-show-all.json (LSI controllers) — per-slot state like JBOD, UGood, Onln, UBad. A drive in JBOD/UBad state cannot join a new virtual disk without first being converted (set good force).
  • "GPU topology / NVLink health?"export/gpu/nvidia-smi-topo.txt (NV# = bonded NVLink pair, PIX/ NODE/SYS = PCIe-only, no NVLink), nvidia-smi-nvlink-status.txt (per-link active/inactive), nvidia-smi-nvlink-errors.txt (replay/ recovery/CRC counters, should be zero), and tasks/bee-sat/nvidia-config-*/summary.txt's nvlink_pairs_checked (how many pairs it found to check, not how many passed). If export/gpu/ also has nvidia-smi-topo-fresh.txt / -nvlink-status-fresh.txt / -nvlink-errors-fresh.txt, those were recaptured live at bundle-build time — prefer them over the non--fresh ones if the two disagree, since the non--fresh files are only as current as the last audit cycle. Not every GPU config has NVLink bridges — check whether this SKU/order is supposed to have them before calling their absence a fault (all-PIX topology, empty nvlink-status/errors files, and nvlink_pairs_checked=0 together mean "none detected," which is only a problem if the config calls for NVLink). If NVLink is expected, one <inactive> lane next to active ones on an otherwise-bonded pair is the real fault signature — a degraded link, not an absent one.
  • "NVIDIA PCIe link speed under real traffic?" -> tasks/bee-sat/gpu-nvidia-bandwidth-*/summary.txt: inspect pcie_link_under_load_status, pcie_gpuN_status, and pcie_degraded. nvidia-pcie-link-under-load-report.txt records each GPU's idle baseline, post-nvbandwidth speed, maximum speed, and negotiated/max width. A Gen1 baseline is informational; only a link still below maximum immediately after real traffic fails. For NICs/HBAs and other non-GPU PCIe devices, use the read-only inventory and AER logs; there is no generic link-speed health verdict without a device-specific traffic generator.
  • "TPM state / validation?"tasks/bee-sat/tpm-*/summary.txt (overall_status plus per-step N-<step>_status); raw dumps in export/platform/tpm-*.txt. Read-only — it never writes the TPM.
  • "What tasks were run from the web UI, in what order, with what result?"tasks/_state/tasks-state.json is the index (id, target, status, timestamps, paths). Each task also has its own directory tasks/<NNN>_<slug>_<done|failed>/ with task.log (live output), report.json/report.html (rendered result + charts).
  • "What build/version is this, and when was it captured?"manifest.txt (bee_version=, generated_at_utc=) at the top level. If the bundle's own folder/file name embeds (BEE-SP vXX.YY), that's the same version, useful for cross-referencing against the bee git repo's release tags if you're checking whether a specific fix shipped in this build.
  • "Was there a CPU/memory/power utilization spike around time T?"status/metrics.db, a SQLite database (sys_metrics table: ts, cpu_load_pct, mem_load_pct, power_w, power_source, power_mode, power_reason). Open with any SQLite client.

Signatures

  • export/platform/ipmitool-sel-time.txt disagrees with manifest.txt's generated_at_utc by more than minutes → BMC RTC drifted → all ipmitool-sel.txt timestamps unreliable; use record-ID order (hex counter, column 1), not printed date.
  • storcli64"Status": "Failure", "Description": "No Controller found" → no legacy MegaRAID controller present, not a drive/RAID fault. Cross-ref storcli2-show-all.json's "Number of Controllers" and lspci/ nvme-list.json for actual storage hardware. Same pattern as nvlink_pairs_checked=0 above.
  • nvidia-pcie-link-under-load-report.txt shows before=Gen1 and after=max at full width -> normal GPU idle power management, not a PCIe downgrade. Treat after < max or width < max_width as a fault only when the paired nvbandwidth command actually ran.
  • systemctl restart ... timed out in a tasks/_services/bee-*.log → implicates a SAT run only if its timestamp is inside that run's run_at_utc/started_atdone_at window in tasks/_state/tasks-state.json; outside that window (e.g. boot bring-up) it's unrelated.
  • SEL sequence Power Supply Failure detected/AC lost (all PSUs) → ACPI Legacy OFFChassis intrusionPower Button pressedLegacy ON → full power-cycle, not a failing PSU. Isolated failure assertion with no OFF/ON bracket, or one PSU failing while siblings stay healthy → real PSU fault.
  • Every conclusion needs a file/line/key citation. Failure/Critical/ timeout/Error matched without reading the surrounding context is not a citation.

Diagnosing "it rebooted/crashed during test X"

  1. tasks/_state/tasks-state.json → task stuck pending/running, or last tasks/bee-sat/<target>-*/ with no summary.txt = check running at crash time.
  2. That directory's verbose.log → last subprocess with no matching finish/exit-code line = the trigger.
  3. livecd/host/dmesg.txt starting at uptime 0, ending after a few hundred seconds = fresh-boot log captured after an unclean reset (confirms unclean reboot; does not contain the crash itself).
  4. Diff against a step that passed cleanly → isolates what's specific to the failing workload (e.g. GPU-to-GPU/NVLink traffic vs. per-GPU compute-only) instead of a generic cause (thermal, power) that would also hit the passing step.

Top-level layout

manifest.txt          bee_version, host, generated_at_utc, export_dir,
                       then a flat "path<TAB>size" listing of every file
                       in this bundle — a quick inventory/sanity check.
README.md             this file — read this first.
export/               raw, vendor-native hardware data, by device type —
                       see "export/" below.
status/               computed diagnosis, not raw data — see below.
tasks/                bee's own task-run bookkeeping — see below.
livecd/               this boot/kiosk session only, not hardware — see below.

export/ in detail

Raw tool/command output, grouped by the physical device it describes. Vendor-neutral: nothing here assumes familiarity with bee.

Path What it is
reanimator.json The master hardware snapshot (see "Fastest answers" above) — ready to POST /ingest/hardware.
cpu/ lscpu.txt, dmidecode-type4.txt (Processor Information).
memory/ dmidecode-type17.txt (Memory Device, one entry per DIMM).
storage/ smartctl-<dev>.json, nvme-id-ctrl-<dev>.json, nvme-smart-log-<dev>.json, nvme-list.json, storcli64-drives.json, storcli2-show-all.json, lsblk.json.
gpu/ nvidia-smi-*.txt/.csv (state/topology/NVLink; -fresh variants are recaptured live at bundle-build time — see "GPU topology" above), dcgmi-nvlink-status.txt, nvidia-bug-report.txt, nvidia-dcgm.service/nvidia-fabricmanager.service status+journal, fabric-manager-paths.txt, fabricmanager.log/nvlsm.log, lspci-nvidia-bridges-vv.txt, pcie-nvidia-link.txt (idle sample — a Gen1
reading here can be normal driver power management, not a fault),
pcie-nvidia-link-under-load.txt (same sysfs attributes resampled while
bee-gpu-burn is actively loading the GPUs; if the link trains up to full
speed here, the idle Gen1 reading was power saving — if it stays at Gen1
under load, that's a real link/riser/slot degradation), pcie-aer-sysfs.txt, kernel-aer-nvidia.txt (AER/NVRM/Xid-filtered dmesg), lspci-video-vv.txt, systemctl-nvidia-units.txt. AMD systems get rocm-smi*.txt here instead.
network/ ethtool-{info,link,module}.txt (per-NIC), mstflint-query.txt (Mellanox/NVIDIA NICs).
platform/ dmidecode-type{0,1,2}.txt (BIOS/System/Baseboard), ipmitool-{fru,sdr,sensor,sel,sel-time}.txt (BMC), tpm-{properties-fixed,pcr-banks,pcr-values,test-result}.txt (read-only TPM state), sensors.json, lspci-{nn,vmm,vvv}.txt.

status/ in detail

Computed diagnosis, not raw data — see "Fastest answers" above for component-status.json and metrics.db.

Path What it is
component-status.json Current rolled-up component health, written by bee's live /dev/kmsg watcher and by SAT run results. Source of reanimator.json's status/status_history fields.
runtime-health.json / .log A lighter, more frequent health snapshot than the full audit — good for "was it fine 5 minutes ago" without the cost of a full re-audit.
metrics.db SQLite time-series (CPU/mem load, power draw/source/mode) — see "Fastest answers" above.

tasks/ in detail

bee's own bookkeeping. Duplication with export/ is expected here — this tier keeps the full story of a specific run, export/ keeps the clean current-state answer.

Path What it is
bee-sat/<target>-<timestamp>/ One directory per acceptance-test run — target is what was tested (gpu-nvidia, cpu, memory, storage, nccl-tests, gpu-nvidia-bandwidth including the NVIDIA PCIe link-under-load verdict, nvidia-config covering GPU config/NVLink/Confidential-Computing readiness, tpm (read-only TPM validation), etc). Each contains summary.txt (key=value, always has overall_status), a full human-readable report (e.g. storage's per-drive disk-NN-<dev>-report.txt — a narrative verdict, not raw tool output; the raw data behind it lives in export/storage/), numbered per-job logs, and verbose.log (every subprocess invocation + exit code — the place to look when a summary doesn't explain why something failed).
bee-bench/ Benchmark run artifacts, if any have been run.
<NNN>_<slug>_<done|failed>/ One directory per task launched from the web UI's task queue — see "Fastest answers" above.
_state/bee-audit.json The full hardware-audit document as bee last generated it — same content as export/reanimator.json, kept here as bee's own internal record.
_state/tasks-state.json Index of every task (id, target, status, timestamps, artifact paths).
_state/blackbox-state.json Present if continuous blackbox capture (mirroring the export dir to removable media on a schedule) is or was active; tracks the sync target and last successful sync.
_services/bee-*.log Per-service startup/runtime logs for each bee-owned systemd unit.
_services/<service>.status.txt, .journal.log, combined.journal.log Captured fresh at bundle-build time, for every bee-owned service (bee-audit, bee-web, bee-network, bee-nvidia, bee-preflight, bee-selfheal, bee-sshsetup, bee-blackbox).

Why a bee service/check might have failed

Before treating a failed/inactive unit as a hardware fault, check whether its own logic is designed to skip or fail under specific benign conditions — several of these look like failures in systemctl status but are expected behavior on that particular machine.

Service / check What normal failure/skip looks like and why
bee-blackbox.service Restarts forever (Restart=always) mirroring export/ to removable media; only a real problem if _state/blackbox-state.json's last-sync timestamp is stale — no USB media present is a common, harmless cause.
bee-nvidia.service Exits 0 and skips entirely if no 10de:0300/0302 (NVIDIA display/3D) PCI function is present, or if /usr/local/bin/bee-nvidia-load is absent (non-NVIDIA build) — not a failure. A real failure is insmod erroring, or (SXM→PCIe conversion boards) GSP firmware entering a crash/reload loop that never populates /proc/devices with nvidiactl within 90s; the script then tries rmmod to fall back to NVreg_EnableGpuFirmware=0 — if rmmod also fails (EBUSY, module stuck), it logs gsp-stuck to /run/bee-nvidia-mode and the machine must be rebooted with bee.nvidia.mode=gsp-off (or nomsi if the dmesg tail shows Failed to enable MSI-X) at the boot menu. See export/gpu/systemctl-nvidia-units.txt and this service's dmesg: lines in its log for the exact symptom.
nvidia-fabricmanager.service (bee-check-nvswitch ExecCondition) Not a failure when inactive. ExecCondition=/usr/local/bin/bee-check-nvswitch decides whether this SKU has an NVSwitch fabric, in order: (1) nvidia-smi -q's GPU Fabric GUID field has a real value (not N/A) — the primary signal, since on platforms like HGX B200 (Kaytus KR9288-X3) NVSwitch is managed via HMC/ERoT and never appears on host-PCIe at all; (2) /proc/driver/nvidia-nvswitch/devices is non-empty; (3) legacy lspci -Dn scan for a vendor 10de class 0680 (Bridge, Other) device, for older HGX generations where NVSwitch is host-PCIe-visible. If all three say no (plain PCIe GPUs / direct NVLink bridges with no switch), the check exits 1 and systemd marks the unit inactive (dead) with condition unmet — never failed. Confirm via systemctl status nvidia-fabricmanager.service showing ConditionResult=no, plus export/gpu/nvidia-smi-topo.txt showing all-PIX topology (see "GPU topology" above) — same signature as nvlink_pairs_checked=0. A stale build with the pre-driver-level lspci-only check will misfire on host-PCIe-invisible NVSwitch platforms (e.g. HGX B200): condition (3) alone always says no, FM is always skipped, and cuInit/NCCL/dcgmi diag then fail with "system not yet initialized" on otherwise-healthy hardware — check bee_version in manifest.txt against the fix if this pattern shows up. An actual fabric-manager fault (real NVSwitch present, condition passes, but ExecStart errors) instead shows up as failed/activating (auto-restart) with training errors in export/gpu/fabricmanager.log/nvlsm.log.
nvidia-dcgm.service Ordered After=bee-nvidia.service; if it starts before device nodes exist, nv-hostengine enumerates zero GPUs and never rescans — bee-nvidia-load works around this by force-restarting it once modules are confirmed loaded, so a stale empty inventory here usually means that restart itself failed or timed out (see bee-nvidia.log's WARN: failed to restart nvidia-dcgm.service / timed out after 60s lines) rather than a DCGM bug.
bee-audit.service / bee-preflight.service bee-preflight deliberately never fails the unit (; exit 0 regardless of the underlying bee preflight return code) — check runtime-health.log's own WARN: preflight exited with rc=N line, not unit status, for a real preflight problem. bee-audit failing outright usually means the underlying bee audit binary hit an unrecoverable collection error; check export/bee-audit.log, not just systemctl status.
bee-network.service Also structured to exit 0 unconditionally — list_interfaces filters out virtual/loopback interfaces, then DHCP is attempted per-NIC with a 300s timeout; a per-interface DHCP failure or timeout is logged (DHCP timed out on <iface> / DHCP failed on <iface>) but does not fail the unit, since a lease-less NIC (no cable, no DHCP server on that segment) is common and not itself a hardware defect. Check bee-network.log's leases acquired: N vs interfaces scanned: N line for the real outcome.
bee-sshsetup.service Fails only on useradd/chpasswd/file-write errors (e.g. read-only /etc), which would be a filesystem problem, not an SSH-specific one. Whether it configures key-only auth or the bee/eeb password fallback is a deliberate branch on /etc/bee-ssh-password-fallback's presence, not a fault either way — check which branch its log took before assuming misconfiguration.
bee-selfheal.service/.timer A oneshot that runs on a timer and restarts other bee services when it detects specific bad states — its own "failure" is rare (only if the lock dir can't be created, or the restart calls themselves fail) but its log content (_services/bee-selfheal.log) is often the fastest place to see which downstream service was unhealthy and had to be kicked: /dev/nvidia0 missing while a GPU is present, an interrupted .tmp write for bee-audit.json/runtime-health.json, bee-web.service inactive, or bee-web's own /healthz endpoint not answering on 127.0.0.1:80.
bee-web.service Restart=always, no MemoryMax (deliberately — it spawns multi-GB GPU stress subprocesses like dcgmproftester that a cgroup limit would OOM-kill); a genuine crash-loop here is unusual and worth its full journal.log, not just the latest restart.
bee-hpc-tuning.service Best-effort CPU governor/C-state tuning ordered before bee-nvidia/bee-audit; failure here (e.g. governor sysfs knobs absent on this CPU/BIOS combination) does not block the rest of boot but can explain unexpectedly poor benchmark numbers if not caught.

livecd/ in detail

Only relevant to this particular live-boot/kiosk session — not the physical hardware. Safe to ignore entirely when troubleshooting hardware.

Path What it is
gui/ Xorg.0.log, lightdm/, xinput-list.txt, libinput-list-devices.txt, drm-cards.txt, proc-fb.txt, input-devices.txt, udevadm-input.txt, loginctl-{sessions,seats}.txt, ps-gui.txt, systemctl-gui-units.txt, home-bee-xsession-errors.log, home-bee-chromium-debug.log, dmesg-gui-video-input.txt (GUI/video/input-filtered dmesg), display-manager.service/lightdm.service status+journal.
host/ uname.txt, cmdline.txt, lsmod.txt, mount.txt, df-h.txt, dmesg.txt (full kernel ring buffer for this boot), ip-{addr,link,link-stats,route}.txt (this session's network config, e.g. DHCP-assigned addresses — not a hardware fact about the NIC itself; NIC hardware/firmware state is in export/network/).