RAID Controller Management showed "No drives detected" for a live
SAS3808-iMR controller even though storcli64 clearly enumerates its
drives. Root cause: the "eall/sall show all J" drive-listing parser
(collector/raid.go and its webui/raid_mgmt.go duplicate) assumed
drives are reported as a single "Drive Information" array, but real
storcli64/storcli2 output nests each drive under its own dynamically
named key ("Drive /c0/e69/s0", paired with a "... - Detailed
Information" key) — confirmed against a live techdump/storcli64-drives.json
capture. The assumed shape was never actually produced by the tool, so
this affected every storcli64/storcli2 controller, not just Tri-Mode
ones (the storcli2 fallback added in b7f015c never got a chance to
mask it in practice, since storcli2 itself reports zero controllers on
this hardware — a separate, unrelated tool-side gap).
Both parsers now read "Response Data" as a raw key map and pull drives
from either shape, so older storcli output using the array form still
works alongside the real per-slot form.
Co-Authored-By: Claude Sonnet 5 <noreply@anthropic.com>
storcli64 enumerates these controllers but reports zero drives; storcli2
is the tool Broadcom ships for Tri-Mode/MegaRAID8 hardware and uses a
compatible JSON schema for drive listing. Wires storcli2 into both the
collector (structured drive data) and the webui RAID Management page
(dedup so a controller isn't double-listed if storcli64 already sees it
with zero drives), plus techdump raw collection and the ISO vendor-tool
build step.
Co-Authored-By: Claude Sonnet 5 <noreply@anthropic.com>
nvme-cli emits large 64-bit counters as JSON-quoted strings on some
versions; the disk-report text generator only handled bare numbers and
{lo,hi} objects, so power_on_hours/data_units_read/data_units_written
etc. silently parsed as 0 while the structured collector path already
handled this correctly. Unify both paths on a single exported
JSONInt64/NVMeSmartLog/NVMeIDCtrl type in collector/storage.go instead
of keeping two independent nvme-cli JSON parsers in sync.
Co-Authored-By: Claude Sonnet 5 <noreply@anthropic.com>
IPMI hang fix (Lenovo XCC SR650 V3):
- Add pluggable ipmi_profile system with per-vendor timeouts and fruEarlyExit flag
- Lenovo profile: 90s FRU timeout, streaming early-exit stops after PSU blocks found
- collectFRUEarlyExit streams ipmitool fru print and kills process once PSU blocks
are followed by a non-PSU header (~6s instead of ~108s on 54-device FRU list)
- collectBMCFirmware and collectPSUs accept manufacturer and apply profile timeouts
VROC license detection:
- Detect VMD/VROC controller in PCIe list, run mdadm --detail-platform
- Parse "License:" line; store as snap.VROCLicense in HardwareSnapshot
Blackbox service fix:
- bee-blackbox.service was missing from systemctl enable list in ISO build hook
- Service never started on boot; state file never written; UI button stayed "Enable"
Drop qrencode:
- Remove from package list, standardTools API check, and runtime-flows doc