- nvidia-smi underlines the topo -m header with ANSI CSI codes even when
writing to a file; both NVLink matrix parsers failed to find the header
and /topo showed "No NVLink-bonded GPU pairs found" on bonded systems.
- raid-lsi-create-mirror failed with "resources already in use" (exit 11)
on JBOD drives; the task now reads drive states and auto-converts
JBOD/UBad (set good force), releases hotspares, refuses Frgn/Onln with
actionable messages, and dumps preservedcache info when add vd fails.
Co-Authored-By: Claude Fable 5 <noreply@anthropic.com>
RAID Controller Management showed "No drives detected" for a live
SAS3808-iMR controller even though storcli64 clearly enumerates its
drives. Root cause: the "eall/sall show all J" drive-listing parser
(collector/raid.go and its webui/raid_mgmt.go duplicate) assumed
drives are reported as a single "Drive Information" array, but real
storcli64/storcli2 output nests each drive under its own dynamically
named key ("Drive /c0/e69/s0", paired with a "... - Detailed
Information" key) — confirmed against a live techdump/storcli64-drives.json
capture. The assumed shape was never actually produced by the tool, so
this affected every storcli64/storcli2 controller, not just Tri-Mode
ones (the storcli2 fallback added in b7f015c never got a chance to
mask it in practice, since storcli2 itself reports zero controllers on
this hardware — a separate, unrelated tool-side gap).
Both parsers now read "Response Data" as a raw key map and pull drives
from either shape, so older storcli output using the array form still
works alongside the real per-slot form.
Co-Authored-By: Claude Sonnet 5 <noreply@anthropic.com>
storcli64 enumerates these controllers but reports zero drives; storcli2
is the tool Broadcom ships for Tri-Mode/MegaRAID8 hardware and uses a
compatible JSON schema for drive listing. Wires storcli2 into both the
collector (structured drive data) and the webui RAID Management page
(dedup so a controller isn't double-listed if storcli64 already sees it
with zero drives), plus techdump raw collection and the ISO vendor-tool
build step.
Co-Authored-By: Claude Sonnet 5 <noreply@anthropic.com>
RAID Controller Management previously hid any LSI drive that wasn't
already Frgn/UGood/JBOD, and scoped VROC "free drives" from all system
disks instead of the ones actually wired to the VROC controller's
ports - drives attached directly to the CPU or another HBA could leak
in. Now every drive is listed per its own controller, and LSI drives
not already ready for array creation get a "Prepare" button that
forces them to Unconfigured Good via storcli.
Co-Authored-By: Claude Sonnet 5 <noreply@anthropic.com>
Unified card for LSI/Broadcom and Intel VROC controllers: auto-detects
foreign configurations and warns the operator with Import/Clear actions;
allows creating RAID 1 mirrors from unconfigured drives regardless of
controller type. Live output streams via SSE into an inline terminal.
Co-Authored-By: Claude Sonnet 4.6 <noreply@anthropic.com>