Commit Graph
7 Commits
Author SHA1 Message Date
Mikhail ChusavitinandClaude Sonnet 5 7ed652c5b1 feat: autotune PSU capacity from the same full-load run as fan ceilings
Extract the fan peak-tracking into observedPeakStore (observe max under
load, hold >= minHold to reject spikes, round, persist JSON) and add a
second instance for PSU draw (psu-observation.json, keyed by PSU
ordinal). Fed from samplePSUPower like fans are from sampleFanSpeeds, so
any full-load run refines it — the Fan Ceiling Check (which also samples
PSU power at a slow cadence off its loop and writes psu_<i>_peak_w), a
burn, thermal cycling, and the 5s web metrics collector.

/topo PSU cards now scale the load fill by wattage_w when the BMC
reports it, else by the observed peak draw — marked "~N% load". This
MSI stand's BMC gives only instantaneous input power, so the observed
peak is the only capacity figure available.

Fan behaviour is unchanged (tests exercise updateFanObservation /
estimateFanDutyCyclePctFromObservation / ResolveFanMaxRPM through the
new store).

Co-Authored-By: Claude Sonnet 5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_019VHG21rgTUiR1G3qFHTVmN
2026-09-04 12:53:13 +03:00
Mikhail ChusavitinandClaude Sonnet 5 bb2a501a28 feat(sat): fan ceiling check + topology fan tiles
Repurpose the previously-unwired RunFanStressTest into RunFanCheck, a
Load-tier SAT test that drives stressapptest (CPU+memory) and, when a GPU
is present, a GPU burn to 100% simultaneously, then watches every fan
until none has climbed for ~60s. The observed peak RPM per fan is the
"ceiling"; it is persisted through the existing fan-observation store.

MSI G4201 / AMI MegaRAC exposes no host-side fan force (every OEM IPMI
command returns 0xc1; Redfish Thermal is GET-only), so load-driven ramp
is the closest safe equivalent. See
bible-local/decisions/2026-09-04-fan-ceiling-check.md.

- platform.ResolveFanMaxRPM: per-fan max with fallback (persisted peak ->
  peer peak -> current RPM), resolved in platform, not the view.
- platform.ErrTestNotApplicable: no load source or no fan sensors ->
  task lands as cancelled ("not applicable"), never failed, so an
  engineer never sees a false red. executeTaskWithOptions maps the
  sentinel; finalizeTaskForResult honours a pre-set TaskCancelled.
- Verdict FAIL only for a fan at 0 RPM / IPMI cr-nr under load.
- /topo: one small spinning square per fan, sized by RPM / resolved max,
  clickable through to a new "fan" component-detail type; per-fan status
  recorded to the component-status DB from the fan SAT summary.
- Wiring: /api/sat/fan/run route, "fan" task target, Load-page card,
  stress-mode Run All.

Co-Authored-By: Claude Sonnet 5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_019VHG21rgTUiR1G3qFHTVmN
2026-09-04 10:35:34 +03:00
mchus b3cf8e3893 Globalize autotuned system power source 2026-04-20 07:02:12 +03:00
Mikhail Chusavitin 18e24a9aa5 Estimate fan duty from observed RPM maxima 2026-04-16 10:10:18 +03:00
Mikhail Chusavitin 8fc986c933 Add benchmark fan duty cycle summary to report 2026-04-14 10:24:02 +03:00
Mikhail Chusavitin c95bbff23b fix(metrics): stabilize cpu and power sampling 2026-04-01 09:40:42 +03:00
mchus 59a1d4b209 release: v3.1 2026-03-28 22:51:36 +03:00