c5b2081ac9 Disable unstable fp4/fp64 benchmark phases 2026-04-16 09:58:02 +03:00
0d925299ff Use per-GPU temperature limits from nvidia-smi -q for headroom calculation
Parse "GPU Shutdown Temp" and "GPU Slowdown Temp" from nvidia-smi -q verbose
output in enrichGPUInfoWithMaxClocks. Store as ShutdownTempC/SlowdownTempC
on benchmarkGPUInfo and BenchmarkGPUResult. Fallback: 90°C shutdown / 80°C
slowdown when not available.

TempHeadroomC = ShutdownTempC - P95TempC (per-GPU, not hardcoded 100°C).
Warning threshold: p95 >= SlowdownTempC. Critical: headroom < 10°C.
Report table shows both limits alongside headroom and p95 temp.

Co-Authored-By: Claude Sonnet 4.6 <noreply@anthropic.com>
2026-04-16 06:45:15 +03:00
a8d5e019a5 Translate report to English; add power anomaly detector
All report strings are now English only.

Add detectPowerAnomaly: scans steady-state metric rows per GPU with a
5-sample rolling baseline; flags a sudden drop ≥30% while GPU usage >50%
as [HARD STOP] — indicates bad cable contact or VRM fault.

Co-Authored-By: Claude Sonnet 4.6 <noreply@anthropic.com>
2026-04-16 06:42:00 +03:00
72ec086568 Restructure benchmark report as balanced scorecard (5 perspectives)
Split throttle into separate signals: ThermalThrottlePct, PowerCapThrottlePct,
SyncBoostThrottlePct. Add TempHeadroomC (100 - p95_temp) as independent
thermal headroom metric; warning < 20°C (>80°C), critical < 10°C (>90°C).

Hard stop findings: thermal throttle with fans < 95%, ECC uncorrected errors,
p95 temp > 90°C. Throttle findings now include per-type percentages and
diagnostic context.

Replace flat scorecard table with BSC 5-perspective layout:
1. Compatibility (hard stops: thermal+fan, ECC)
2. Thermal headroom (p95 temp, delta to 100°C, throttle %)
3. Power delivery (power cap throttle, power CV, fan duty)
4. Performance (Compute TOPS, Synthetic, Mixed, TOPS/SM/GHz)
5. Anomalies (ECC corrected, sync boost, power/thermal variance)

Co-Authored-By: Claude Sonnet 4.6 <noreply@anthropic.com>
2026-04-16 06:40:06 +03:00
7a0b0934df Separate compute score from server quality score
CompositeScore = raw ComputeScore (TOPS). Throttling GPUs score lower
automatically — no quality multiplier distorting the compute signal.

Add ServerQualityScore (0-100): server infrastructure quality independent
of GPU model. Formula: 0.40×Stability + 0.30×PowerSustain + 0.30×Thermal.
Use to compare servers with the same GPU or flag bad server conditions.

Co-Authored-By: Claude Sonnet 4.6 <noreply@anthropic.com>
2026-04-16 00:45:55 +03:00
d8ca0dca2c Redesign scoring metrics: variance-based sustain scores, throttle stability
PowerSustainScore: power draw variance (CV) during load, not deviation from TDP.
ThermalSustainScore: temperature variance (CV) during load.
StabilityScore: fraction of time spent in thermal+power-cap throttling.
Remove NCCL bonus from quality_factor.

quality = 0.35 + 0.35×Stability + 0.15×PowerSustain + 0.15×ThermalSustain, cap 1.00.

Co-Authored-By: Claude Sonnet 4.6 <noreply@anthropic.com>
2026-04-16 00:39:59 +03:00
8d6eaef5de Update perf benchmark report methodology to reflect new design
Remove references to pre-benchmark power calibration and dcgmi
targeted_power. Document platform_power_score ramp-up methodology,
PowerSustainScore fallback to steady-state power, and full-budget
single-precision phases.

Co-Authored-By: Claude Sonnet 4.6 <noreply@anthropic.com>
2026-04-16 00:31:58 +03:00
732bf4cbab Redesign power and performance benchmarks with new methodology
Power/Thermal Fit: cumulative fixed-limit ramp where each GPU's stable TDP
is found under real multi-GPU thermal load (all prior GPUs running at their
fixed limits). PlatformMaxTDPW = sum of stable limits across all GPUs.
Remove PlatformPowerScore from power test.

Performance Benchmark: remove pre-benchmark power calibration entirely.
After N single-card runs, execute k=2..N parallel ramp-up steps and compute
PlatformPowerScore = mean compute scalability vs best single-card TOPS.
PowerSustainScore falls back to Steady.AvgPowerW when calibration absent.

Co-Authored-By: Claude Sonnet 4.6 <noreply@anthropic.com>
2026-04-16 00:30:50 +03:00
Mikhail Chusavitin
95124d228f Split bee-bench into perf and power workflows 2026-04-14 17:33:13 +03:00
Mikhail Chusavitin
2be7ae6d28 Refine NVIDIA benchmark phase timing 2026-04-14 14:12:06 +03:00
Mikhail Chusavitin
8fc986c933 Add benchmark fan duty cycle summary to report 2026-04-14 10:24:02 +03:00
bf182daa89 Fix benchmark report methodology and rebuild gpu burn worker on toolchain changes 2026-04-13 23:43:12 +03:00
457ea1cf04 Unify benchmark exports and drop ASCII charts 2026-04-13 21:38:28 +03:00
bf6ecab4f0 Add per-precision benchmark phases, weighted TOPS scoring, and ECC tracking
- Split steady window into 6 equal slots: fp8/fp16/fp32/fp64/fp4 + combined
- Each precision phase runs bee-gpu-burn with --precision filter so PowerCVPct reflects single-kernel stability (not round-robin artifact)
- Add fp4 support in bee-gpu-stress.c for Blackwell (cc>=100) via existing CUDA_R_4F_E2M1 guard
- Weighted TOPS: fp64×2.0, fp32×1.0, fp16×0.5, fp8×0.25, fp4×0.125
- SyntheticScore = sum of weighted TOPS from per-precision phases
- MixedScore = sum from combined phase; MixedEfficiency = Mixed/Synthetic
- ComputeScore = SyntheticScore × (1 + MixedEfficiency × 0.3)
- ECC volatile counters sampled before/after each phase and overall
- DegradationReasons: ecc_uncorrected_errors, ecc_corrected_errors
- Report: per-precision stability table with ECC columns, methodology section
- Ramp-up history table redesign: GPU indices as columns, runs as rows

Co-Authored-By: Claude Sonnet 4.6 <noreply@anthropic.com>
2026-04-13 10:49:49 +03:00
813e2f86a9 Add scalability/ramp-up labeling, ServerPower penalty in scoring, and report improvements
- Add RampStep/RampTotal/RampRunID to NvidiaBenchmarkOptions, taskParams, and
  NvidiaBenchmarkResult so ramp-up steps can be correlated across result.json files
- Add ScalabilityScore field to NvidiaBenchmarkResult (placeholder; computed externally
  by comparing ramp-up step results sharing the same ramp_run_id)
- Propagate ramp fields through api.go (generates shared ramp_run_id at spawn time),
  tasks.go handler, and benchmark.go result population
- Apply ServerPower penalty to CompositeScore when IPMI reporting_ratio < 0.75:
  factor = ratio/0.75, applied per-GPU with a note explaining the reduction
- Add finding when server power delta exceeds GPU-reported sum by >25% (non-GPU draw)
- Report header now shows ramp step N/M and run ID instead of "parallel" when in ramp mode;
  shows scalability_score when non-zero

Co-Authored-By: Claude Sonnet 4.6 <noreply@anthropic.com>
2026-04-12 22:30:47 +03:00
ba16021cdb Fix GPU model propagation, export filenames, PSU/service status, and chart perf
- nvidia.go: add Name field to nvidiaGPUInfo, include model name in
  nvidia-smi query, set dev.Model in enrichPCIeWithNVIDIAData
- pages.go: fix duplicate GPU count in validate card summary (4 GPU: 4 x …
  → 4 x … GPU); fix PSU UNKNOWN fallback from hw.PowerSupplies; treat
  activating/deactivating/reloading service states as OK in Runtime Health
- support_bundle.go: use "150405" time format (no colons) for exFAT compat
- sat.go / benchmark.go / platform_stress.go / sat_fan_stress.go: remove
  .tar.gz archive creation from export dirs — export packs everything itself
- charts_svg.go: add min-max downsampling (1400 pt cap) for SVG chart perf
- benchmark_report.go / sat.go: normalize GPU fallback to "Unknown GPU"

Co-Authored-By: Claude Sonnet 4.6 <noreply@anthropic.com>
2026-04-11 10:05:27 +03:00
b2f8626fee Refactor validate modes, fix benchmark report and IPMI power
- Replace diag level 1-4 dropdown with Validate/Stress radio buttons
- Validate: dcgmi L2, 60s CPU, 256MB/1p memtester, SMART short
- Stress: dcgmi L3 + targeted_stress in Run All, 30min CPU, 1GB/3p memtester, SMART long/NVMe extended
- Parallel GPU mode: spawn single task for all GPUs instead of splitting per model
- Benchmark table: per-GPU columns for sequential runs, server-wide column for parallel
- Benchmark report converted to Markdown with server model, GPU model, version in header; only steady-state charts
- Fix IPMI power parsing in benchmark (was looking for 'Current Power', correct field is 'Instantaneous power reading')

Co-Authored-By: Claude Sonnet 4.6 <noreply@anthropic.com>
2026-04-08 00:42:12 +03:00
d973231f37 Enhance benchmark: server power via IPMI, efficiency metrics, FP64, power limit check
- Sample server power (IPMI dcmi) during baseline+steady phases in parallel;
  compute delta vs GPU-reported sum; flag ratio < 0.75 as unreliable reporting
- Collect base_graphics_clock_mhz, multiprocessor_count, default_power_limit_w
  from nvidia-smi alongside existing GPU info
- Add tops_per_sm_per_ghz efficiency metric (model-agnostic silicon quality signal)
- Flag when enforced power limit is below default TDP by >5%
- Add fp64 profile to bee-gpu-burn worker (CUDA_R_64F, CUBLAS_COMPUTE_64F, min cc 8.0)
- Improve Executive Summary: overall pass count, FAILED GPU finding
- Throttle counters now shown as % of steady window instead of raw microseconds
- bible-local: clock calibration research, H100/H200 spec, real-world GEMM baselines

Co-Authored-By: Claude Sonnet 4.6 <noreply@anthropic.com>
2026-04-06 22:26:52 +03:00
Mikhail Chusavitin
a98c4d7461 Include terminal charts in benchmark report 2026-04-06 12:34:57 +03:00
bf47c8dbd2 Add NVIDIA benchmark reporting flow 2026-04-05 10:30:56 +03:00