Repurpose the previously-unwired RunFanStressTest into RunFanCheck, a
Load-tier SAT test that drives stressapptest (CPU+memory) and, when a GPU
is present, a GPU burn to 100% simultaneously, then watches every fan
until none has climbed for ~60s. The observed peak RPM per fan is the
"ceiling"; it is persisted through the existing fan-observation store.
MSI G4201 / AMI MegaRAC exposes no host-side fan force (every OEM IPMI
command returns 0xc1; Redfish Thermal is GET-only), so load-driven ramp
is the closest safe equivalent. See
bible-local/decisions/2026-09-04-fan-ceiling-check.md.
- platform.ResolveFanMaxRPM: per-fan max with fallback (persisted peak ->
peer peak -> current RPM), resolved in platform, not the view.
- platform.ErrTestNotApplicable: no load source or no fan sensors ->
task lands as cancelled ("not applicable"), never failed, so an
engineer never sees a false red. executeTaskWithOptions maps the
sentinel; finalizeTaskForResult honours a pre-set TaskCancelled.
- Verdict FAIL only for a fan at 0 RPM / IPMI cr-nr under load.
- /topo: one small spinning square per fan, sized by RPM / resolved max,
clickable through to a new "fan" component-detail type; per-fan status
recorded to the component-status DB from the fan SAT summary.
- Wiring: /api/sat/fan/run route, "fan" task target, Load-page card,
stress-mode Run All.
Co-Authored-By: Claude Sonnet 5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_019VHG21rgTUiR1G3qFHTVmN
- Replace diag level 1-4 dropdown with Validate/Stress radio buttons
- Validate: dcgmi L2, 60s CPU, 256MB/1p memtester, SMART short
- Stress: dcgmi L3 + targeted_stress in Run All, 30min CPU, 1GB/3p memtester, SMART long/NVMe extended
- Parallel GPU mode: spawn single task for all GPUs instead of splitting per model
- Benchmark table: per-GPU columns for sequential runs, server-wide column for parallel
- Benchmark report converted to Markdown with server model, GPU model, version in header; only steady-state charts
- Fix IPMI power parsing in benchmark (was looking for 'Current Power', correct field is 'Instantaneous power reading')
Co-Authored-By: Claude Sonnet 4.6 <noreply@anthropic.com>
- tasks: mark TaskRunning tasks as TaskFailed on bee-web restart instead of
re-queueing them — prevents duplicate gpu-burn-worker spawns when bee-web
crashes mid-test (each restart was launching a new set of 8 workers on top
of still-alive orphans from the previous crash)
- server: reduce metrics collector interval 1s→5s, grow ring buffer to 360
samples (30 min); cuts nvidia-smi/ipmitool/sensors subprocess rate by 5×
- platform: add KillTestWorkers() — scans /proc and SIGKILLs bee-gpu-burn,
stress-ng, stressapptest, memtester without relying on pkill/killall
- webui: add "Kill Workers" button next to Cancel All; calls
POST /api/tasks/kill-workers which cancels the task queue then kills
orphaned OS-level processes; shows toast with killed count
- metricsdb: sort GPU indices and fan/temp names after map iteration to fix
non-deterministic sample reconstruction order (flaky test)
- server: fix chartYAxisNumber to use one decimal place for 1000–9999
(e.g. "1,7к" instead of "2к") so Y-axis ticks are distinguishable
Co-Authored-By: Claude Sonnet 4.6 <noreply@anthropic.com>