mchusandClaude Fable 5 10557ec0f6 webui/collector: strip ANSI escapes in nvidia-smi topo parsing, auto-prepare drives for RAID mirror creation
- nvidia-smi underlines the topo -m header with ANSI CSI codes even when
  writing to a file; both NVLink matrix parsers failed to find the header
  and /topo showed "No NVLink-bonded GPU pairs found" on bonded systems.
- raid-lsi-create-mirror failed with "resources already in use" (exit 11)
  on JBOD drives; the task now reads drive states and auto-converts
  JBOD/UBad (set good force), releases hotspares, refuses Frgn/Onln with
  actionable messages, and dumps preservedcache info when add vd fails.

Co-Authored-By: Claude Fable 5 <noreply@anthropic.com>
2026-07-08 23:16:04 +03:00
Mikhail ChusavitinandClaude Sonnet 5 4e306ff78c raid: parse storcli64/storcli2's actual per-slot drive JSON shape
RAID Controller Management showed "No drives detected" for a live
SAS3808-iMR controller even though storcli64 clearly enumerates its
drives. Root cause: the "eall/sall show all J" drive-listing parser
(collector/raid.go and its webui/raid_mgmt.go duplicate) assumed
drives are reported as a single "Drive Information" array, but real
storcli64/storcli2 output nests each drive under its own dynamically
named key ("Drive /c0/e69/s0", paired with a "... - Detailed
Information" key) — confirmed against a live techdump/storcli64-drives.json
capture. The assumed shape was never actually produced by the tool, so
this affected every storcli64/storcli2 controller, not just Tri-Mode
ones (the storcli2 fallback added in b7f015c never got a chance to
mask it in practice, since storcli2 itself reports zero controllers on
this hardware — a separate, unrelated tool-side gap).

Both parsers now read "Response Data" as a raw key map and pull drives
from either shape, so older storcli output using the array form still
works alongside the real per-slot form.

Co-Authored-By: Claude Sonnet 5 <noreply@anthropic.com>
2026-07-07 17:21:05 +03:00
Mikhail ChusavitinandClaude Sonnet 5 b7f015c713 raid: add storcli2 support for Tri-Mode controllers (SAS3808-iMR/9500 series)
storcli64 enumerates these controllers but reports zero drives; storcli2
is the tool Broadcom ships for Tri-Mode/MegaRAID8 hardware and uses a
compatible JSON schema for drive listing. Wires storcli2 into both the
collector (structured drive data) and the webui RAID Management page
(dedup so a controller isn't double-listed if storcli64 already sees it
with zero drives), plus techdump raw collection and the ISO vendor-tool
build step.

Co-Authored-By: Claude Sonnet 5 <noreply@anthropic.com>
2026-07-07 15:25:06 +03:00