Align hardware export with ingest contract
This commit is contained in:
@@ -1,6 +1,10 @@
|
||||
package collector
|
||||
|
||||
import "testing"
|
||||
import (
|
||||
"bee/audit/internal/schema"
|
||||
"errors"
|
||||
"testing"
|
||||
)
|
||||
|
||||
func TestParseSASIrcuControllerIDs(t *testing.T) {
|
||||
raw := `LSI Corporation SAS2 IR Configuration Utility.
|
||||
@@ -90,7 +94,111 @@ physicaldrive 1I:1:2 (894 GB, SAS HDD, Failed)
|
||||
if drives[0].Status == nil || *drives[0].Status != "OK" {
|
||||
t.Fatalf("drive0 status: %v", drives[0].Status)
|
||||
}
|
||||
if drives[1].Status == nil || *drives[1].Status != "CRITICAL" {
|
||||
if drives[1].Status == nil || *drives[1].Status != statusCritical {
|
||||
t.Fatalf("drive1 status: %v", drives[1].Status)
|
||||
}
|
||||
}
|
||||
|
||||
func TestParseStorcliControllerTelemetry(t *testing.T) {
|
||||
raw := []byte(`{
|
||||
"Controllers": [
|
||||
{
|
||||
"Response Data": {
|
||||
"BBU_Info": {
|
||||
"State of Health": "98 %",
|
||||
"Relative State of Charge": "76 %",
|
||||
"Temperature": "41 C",
|
||||
"Voltage": "12.3 V",
|
||||
"Replacement required": "No"
|
||||
}
|
||||
}
|
||||
}
|
||||
]
|
||||
}`)
|
||||
got := parseStorcliControllerTelemetry(raw)
|
||||
if len(got) != 1 {
|
||||
t.Fatalf("len(got)=%d want 1", len(got))
|
||||
}
|
||||
if got[0].BatteryHealthPct == nil || *got[0].BatteryHealthPct != 98 {
|
||||
t.Fatalf("battery health=%v", got[0].BatteryHealthPct)
|
||||
}
|
||||
if got[0].BatteryChargePct == nil || *got[0].BatteryChargePct != 76 {
|
||||
t.Fatalf("battery charge=%v", got[0].BatteryChargePct)
|
||||
}
|
||||
if got[0].BatteryTemperatureC == nil || *got[0].BatteryTemperatureC != 41 {
|
||||
t.Fatalf("battery temperature=%v", got[0].BatteryTemperatureC)
|
||||
}
|
||||
if got[0].BatteryVoltageV == nil || *got[0].BatteryVoltageV != 12.3 {
|
||||
t.Fatalf("battery voltage=%v", got[0].BatteryVoltageV)
|
||||
}
|
||||
if got[0].BatteryReplaceRequired == nil || *got[0].BatteryReplaceRequired {
|
||||
t.Fatalf("battery replace=%v", got[0].BatteryReplaceRequired)
|
||||
}
|
||||
}
|
||||
|
||||
func TestParseSSACLIControllerTelemetry(t *testing.T) {
|
||||
raw := `Smart Array P440ar in Slot 0
|
||||
Battery/Capacitor Count: 1
|
||||
Capacitor Temperature (C): 37
|
||||
Capacitor Charge (%): 94
|
||||
Capacitor Health (%): 96
|
||||
Capacitor Voltage (V): 9.8
|
||||
Capacitor Failed: No
|
||||
`
|
||||
got := parseSSACLIControllerTelemetry(raw)
|
||||
if len(got) != 1 {
|
||||
t.Fatalf("len(got)=%d want 1", len(got))
|
||||
}
|
||||
if got[0].BatteryTemperatureC == nil || *got[0].BatteryTemperatureC != 37 {
|
||||
t.Fatalf("battery temperature=%v", got[0].BatteryTemperatureC)
|
||||
}
|
||||
if got[0].BatteryChargePct == nil || *got[0].BatteryChargePct != 94 {
|
||||
t.Fatalf("battery charge=%v", got[0].BatteryChargePct)
|
||||
}
|
||||
}
|
||||
|
||||
func TestEnrichPCIeWithRAIDTelemetry(t *testing.T) {
|
||||
orig := raidToolQuery
|
||||
t.Cleanup(func() { raidToolQuery = orig })
|
||||
raidToolQuery = func(name string, args ...string) ([]byte, error) {
|
||||
switch name {
|
||||
case "storcli64":
|
||||
return []byte(`{
|
||||
"Controllers": [
|
||||
{
|
||||
"Response Data": {
|
||||
"CV_Info": {
|
||||
"State of Health": "99 %",
|
||||
"Relative State of Charge": "81 %",
|
||||
"Temperature": "38 C",
|
||||
"Voltage": "12.1 V",
|
||||
"Replacement required": "No"
|
||||
}
|
||||
}
|
||||
}
|
||||
]
|
||||
}`), nil
|
||||
default:
|
||||
return nil, errors.New("skip")
|
||||
}
|
||||
}
|
||||
|
||||
vendor := vendorBroadcomLSI
|
||||
class := "MassStorageController"
|
||||
status := statusOK
|
||||
devs := []schema.HardwarePCIeDevice{{
|
||||
VendorID: &vendor,
|
||||
DeviceClass: &class,
|
||||
HardwareComponentStatus: schema.HardwareComponentStatus{Status: &status},
|
||||
}}
|
||||
out := enrichPCIeWithRAIDTelemetry(devs)
|
||||
if out[0].BatteryHealthPct == nil || *out[0].BatteryHealthPct != 99 {
|
||||
t.Fatalf("battery health=%v", out[0].BatteryHealthPct)
|
||||
}
|
||||
if out[0].BatteryChargePct == nil || *out[0].BatteryChargePct != 81 {
|
||||
t.Fatalf("battery charge=%v", out[0].BatteryChargePct)
|
||||
}
|
||||
if out[0].BatteryVoltageV == nil || *out[0].BatteryVoltageV != 12.1 {
|
||||
t.Fatalf("battery voltage=%v", out[0].BatteryVoltageV)
|
||||
}
|
||||
}
|
||||
|
||||
Reference in New Issue