fix(webui): don't show PSU load % until the observed peak clears idle draw
The passive collector records PSU draw at idle too, so right after boot the "observed peak" is just idle wattage and a load % off it is meaningless. Require the observed peak to sit >=25% above current draw before using it as a load scale; until a real full-load run bumps it, show plain watts. Co-Authored-By: Claude Sonnet 5 <noreply@anthropic.com> Claude-Session: https://claude.ai/code/session_019VHG21rgTUiR1G3qFHTVmN
This commit is contained in:
co-authored by
Claude Sonnet 5
parent
7ed652c5b1
commit
08044c81e7
@@ -643,11 +643,14 @@ func renderTopoPSURow(psus []schema.HardwarePowerSupply, observedMaxW map[string
|
|||||||
if p.WattageW != nil && *p.WattageW > 0 {
|
if p.WattageW != nil && *p.WattageW > 0 {
|
||||||
rating = *p.WattageW
|
rating = *p.WattageW
|
||||||
}
|
}
|
||||||
// Load scale: true rating if known, else the observed peak draw.
|
// Load scale: true rating if known, else the observed peak draw — but
|
||||||
|
// only once that peak sits meaningfully above the current draw. Until
|
||||||
|
// a real full-load run has bumped it, the "peak" is just idle draw and
|
||||||
|
// a load % off it would be nonsense, so fall back to plain watts.
|
||||||
scaleMax := float64(rating)
|
scaleMax := float64(rating)
|
||||||
scaleEstimate := false
|
scaleEstimate := false
|
||||||
if scaleMax <= 0 {
|
if scaleMax <= 0 {
|
||||||
if m := observedMaxW[strconv.Itoa(i)]; m > 0 {
|
if m := observedMaxW[strconv.Itoa(i)]; m > 0 && (!haveDraw || m >= draw*1.25) {
|
||||||
scaleMax = m
|
scaleMax = m
|
||||||
scaleEstimate = true
|
scaleEstimate = true
|
||||||
}
|
}
|
||||||
|
|||||||
Reference in New Issue