Files
logpile/internal/server/handlers_serials_test.go
T
Mikhail ChusavitinandClaude Opus 5.5 c4870cfb36 fix(topology): attach SNC/NPS NUMA nodes to their real socket
Topology mapped one NUMA node per CPU, so on a 2-socket SNC2 host
(nodes 0-3) node 1 went to CPU1 and nodes 2-3 got no CPU: the second
BlueField-3, four GPUs and several NICs rendered unattached.

Use numa-nodes.txt (node=N package=P), now carried by parser v26 as
TopologyEvidence.NUMANodes; without it, fall back to contiguous
per-socket blocks of zero-based node ids. Pin parser v26.0.0. ADL-082.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
2026-10-19 13:41:22 +03:00

21 lines
689 B
Go

package server
import (
"git.mchus.pro/reanimator/parser/v26/models"
"testing"
)
func TestNormalizePCIeSerialComponentName_PrefersPartOverGenericClass(t *testing.T) {
got := normalizePCIeSerialComponentName(models.PCIeDevice{DeviceClass: "Display Controller", PartNumber: "GH100 [H200 NVL]"})
if got != "GH100 [H200 NVL]" {
t.Fatalf("expected part number, got %q", got)
}
}
func TestNormalizePCIeSerialComponentName_UsesClassWhenSpecific(t *testing.T) {
got := normalizePCIeSerialComponentName(models.PCIeDevice{DeviceClass: "I350 Gigabit Network Connection", PartNumber: "I350T4V2"})
if got != "I350T4V2" {
t.Fatalf("expected part number for readability, got %q", got)
}
}