BMC readiness after power-on (waitForStablePoweredOnHost):
- After initial 1m stabilization, poll BMC inventory readiness before collecting
- Ready if MemorySummary.TotalSystemMemoryGiB > 0 OR PCIeDevices.Members non-empty
- On failure: wait +60s, retry; on second failure: wait +120s, retry; then warn and proceed
- Configurable via LOGPILE_REDFISH_BMC_READY_WAITS (default: 60s,120s)
Empty critical collection plan-B retry (EnableEmptyCriticalCollectionRetry):
- Hardware inventory collections that returned Members=[] are now re-probed in plan-B
- Covers PCIeDevices, NetworkAdapters, Processors, Drives, Storage, EthernetInterfaces
- Enabled by default in generic profile (applies to all vendors)
Ghost NIC dedup fix (enrichNICsFromNetworkInterfaces):
- NetworkInterface entries (e.g. Id=2) that don't match existing NIC slots are now
resolved via Links.NetworkAdapter cross-reference to the real Chassis NIC
- Prevents duplicate ghost entries (slot=2 "Network Device View") from appearing
alongside real NICs (slot="RISER 5 slot 1 (7)") with the same MAC addresses
Co-Authored-By: Claude Sonnet 4.6 <noreply@anthropic.com>
Matches on ServiceRootVendor "xFusion" and OEM namespace "xFusion"
(score 90+). Enables GenericGraphicsControllerDedup unconditionally and
ProcessorGPUFallback when GPU-type processors are present in the snapshot
(xFusion G5500 V7 exposes H200s simultaneously in PCIeDevices,
GraphicsControllers, and Processors/Gpu* — all three need dedup).
Without this profile, xFusion fell into fallback mode which activated all
vendor profiles (Supermicro, HGX, MSI, Dell) unnecessarily. Now resolves
to matched mode with targeted acquisition tuning (120k cap, 75s baseline).
Co-Authored-By: Claude Sonnet 4.6 <noreply@anthropic.com>
Implement the full architectural plan: unified ingest.Service entry point
for archive and Redfish payloads, modular redfishprofile package with
composable profiles (generic, ami-family, msi, supermicro, dell,
hgx-topology), score-based profile matching with fallback expansion mode,
and profile-driven acquisition/analysis plans.
Vendor-specific logic moved out of common executors and into profile hooks.
GPU chassis lookup strategies and known storage recovery collections
(IntelVROC/HA-RAID/MRVL) now live in ResolvedAnalysisPlan, populated by
profiles at analysis time. Replay helpers read from the plan; no hardcoded
path lists remain in generic code.
Also splits redfish_replay.go into domain modules (gpu, storage, inventory,
fru, profiles) and adds full fixture/matcher/directive test coverage
including Dell, AMI, unknown-vendor fallback, and deterministic ordering.
Co-Authored-By: Claude Sonnet 4.6 <noreply@anthropic.com>