Commit Graph
4 Commits
Author SHA1 Message Date
mchusandClaude Sonnet 5 74e6bf0578 fix(parser): support Inspur HGX dump_<serial>_<timestamp>/ onekeylog layout
Fixes #20. This onekeylog variant has no devicefrusdr.log at all: FRU/sensors
come from raw ipmitool text output, PCIe/GPU presence has a dedicated
structural snapshot, SEL lives at a different path, and BMC component
failures are logged separately from SEL/IDL.

- Fall back to component/fru.txt (same FRU block format as devicefrusdr.log)
  and component/sensor.txt / sdr.txt (ipmitool sensor list / sdr elist)
  when devicefrusdr.log is absent.
- Parse log/bmc/diagnose/OtrdDiagnoseComponent.json's PCIe Device Info array
  for GPU/PCIe presence and link state, independent of SEL/IDL alarm
  history; flag devices running below their negotiated max link
  speed/width as degraded with a Warning event.
- Fall back to log/sel.csv (same format as selelist.csv) when selelist.csv
  is absent.
- Parse log/bmc/commer-comp/{commerslot,commerhmc,commerswvr,commerswcpld}
  logs (including rotated *.tar.gz.N parts) into failure events, filtering
  known-noisy lines.
- Collapse SEL events duplicated across sources by
  (timestamp, event_type, description).
- Surface a CollectionError when FRU/sensors are still empty after all
  fallbacks, instead of silently returning an empty inventory.
- Fix ParseFRU: a later placeholder "Product Serial : 0" / "Product Part
  Number : NULL" line in the same FRU block (e.g. SCM_FRU) was overwriting
  an already-parsed real Board Serial/Part Number.

Verified against dump_23DB01633_20260727-1359.tar.gz (HGX B200, KR9288-X3):
fru 0→21, sensors 0→303, 8 GPUs present at Gen5 x16 in slots 100-107.

Deferred (not covered by this change): BIOS-change-settings context and
BIOS POST codes from the same layout — see bible-local/10-decisions.md
ADL-048.

Co-Authored-By: Claude Sonnet 5 <noreply@anthropic.com>
2026-07-29 10:05:58 +03:00
mchus 5e49adaf05 Update parser and project changes 2026-02-15 22:02:07 +03:00
mchusandClaude Opus 4.5 c7422e95aa v1.1.0: Parser versioning, server info, auto-browser, section overviews
- Add parser versioning with Version() method and version display on main screen
- Add server model and serial number to Configuration tab and TXT export
- Add auto-browser opening on startup with --no-browser flag
- Add Restart and Exit buttons with graceful shutdown
- Add section overview stats (CPU, Power, Storage, GPU, Network)
- Change PCIe Link display to "x16 PCIe Gen4" format
- Add Location column to Serials section
- Extract BoardInfo from FRU and PlatformId from ThermalConfig

Co-Authored-By: Claude Opus 4.5 <noreply@anthropic.com>
2026-01-25 13:49:43 +03:00
mchusandClaude Opus 4.5 512957545a Add LOGPile BMC diagnostic log analyzer
Features:
- Modular parser architecture for vendor-specific formats
- Inspur/Kaytus parser supporting asset.json, devicefrusdr.log,
  component.log, idl.log, and syslog files
- PCI Vendor/Device ID lookup for hardware identification
- Web interface with tabs: Events, Sensors, Config, Serials, Firmware
- Server specification summary with component grouping
- Export to CSV, JSON, TXT formats
- BMC alarm parsing from IDL logs (memory errors, PSU events, etc.)

Co-Authored-By: Claude Opus 4.5 <noreply@anthropic.com>