looksLikeGPU now falls back to resolving VendorId/DeviceId through the
pci.ids database when the BMC leaves Name/Model/Manufacturer/ClassCode
empty, so GPUs identifiable only by raw PCI IDs (e.g. NVIDIA H100 SXM5
0x10de/0x2330) are no longer misclassified as generic PCIe devices.
The replay pipeline's "backed by canonical NIC" dedup used to trust a
PCIeDevice's Links.NetworkDeviceFunctions reference at face value and
drop the device, assuming a NetworkAdapters record existed elsewhere.
On BMCs that expose resource IDs with characters (parentheses) that
404 on fetch, that canonical NIC never gets captured, so the device
carrying its actual hardware identity vanished from the export
entirely. hasResolvableLinkedMember now verifies the linked resource
is actually present in the snapshot before treating it as authoritative.
Also normalize PartNumber through normalizeRedfishIdentityField in the
GPU/PCIe parsers so a BMC-supplied literal "null" string doesn't leak
into exports verbatim.
Co-Authored-By: Claude Sonnet 5 <noreply@anthropic.com>
BMC readiness after power-on (waitForStablePoweredOnHost):
- After initial 1m stabilization, poll BMC inventory readiness before collecting
- Ready if MemorySummary.TotalSystemMemoryGiB > 0 OR PCIeDevices.Members non-empty
- On failure: wait +60s, retry; on second failure: wait +120s, retry; then warn and proceed
- Configurable via LOGPILE_REDFISH_BMC_READY_WAITS (default: 60s,120s)
Empty critical collection plan-B retry (EnableEmptyCriticalCollectionRetry):
- Hardware inventory collections that returned Members=[] are now re-probed in plan-B
- Covers PCIeDevices, NetworkAdapters, Processors, Drives, Storage, EthernetInterfaces
- Enabled by default in generic profile (applies to all vendors)
Ghost NIC dedup fix (enrichNICsFromNetworkInterfaces):
- NetworkInterface entries (e.g. Id=2) that don't match existing NIC slots are now
resolved via Links.NetworkAdapter cross-reference to the real Chassis NIC
- Prevents duplicate ghost entries (slot=2 "Network Device View") from appearing
alongside real NICs (slot="RISER 5 slot 1 (7)") with the same MAC addresses
Co-Authored-By: Claude Sonnet 4.6 <noreply@anthropic.com>
Implement the full architectural plan: unified ingest.Service entry point
for archive and Redfish payloads, modular redfishprofile package with
composable profiles (generic, ami-family, msi, supermicro, dell,
hgx-topology), score-based profile matching with fallback expansion mode,
and profile-driven acquisition/analysis plans.
Vendor-specific logic moved out of common executors and into profile hooks.
GPU chassis lookup strategies and known storage recovery collections
(IntelVROC/HA-RAID/MRVL) now live in ResolvedAnalysisPlan, populated by
profiles at analysis time. Replay helpers read from the plan; no hardcoded
path lists remain in generic code.
Also splits redfish_replay.go into domain modules (gpu, storage, inventory,
fru, profiles) and adds full fixture/matcher/directive test coverage
including Dell, AMI, unknown-vendor fallback, and deterministic ordering.
Co-Authored-By: Claude Sonnet 4.6 <noreply@anthropic.com>