Commit Graph
18 Commits
Author SHA1 Message Date
mchusandClaude Sonnet 5 586ac782b2 fix(parser): expose NVIDIA HGX tray/baseboard identity separately from vendor carrier FRU
Inspur/Kaytus onekeylog dumps only exposed the mechanical carrier FRU serial
(component/fru.txt Board Product) as board identity. That serial doesn't
change when the actual NVIDIA HGX baseboard (SXM+NVSwitch "delta board") is
swapped, causing false "board unchanged" conclusions. Parse the real HGX
tray/baseboard Model/PartNumber/SerialNumber triples from
HGX_HWInfo_FWVersion.log into a new HardwareConfig.HGX field, and normalize
Redfish's NA/N-A placeholders to empty across HGX identity parsing.

Closes #21

Co-Authored-By: Claude Sonnet 5 <noreply@anthropic.com>
2026-07-29 10:30:54 +03:00
mchusandClaude Sonnet 5 74e6bf0578 fix(parser): support Inspur HGX dump_<serial>_<timestamp>/ onekeylog layout
Fixes #20. This onekeylog variant has no devicefrusdr.log at all: FRU/sensors
come from raw ipmitool text output, PCIe/GPU presence has a dedicated
structural snapshot, SEL lives at a different path, and BMC component
failures are logged separately from SEL/IDL.

- Fall back to component/fru.txt (same FRU block format as devicefrusdr.log)
  and component/sensor.txt / sdr.txt (ipmitool sensor list / sdr elist)
  when devicefrusdr.log is absent.
- Parse log/bmc/diagnose/OtrdDiagnoseComponent.json's PCIe Device Info array
  for GPU/PCIe presence and link state, independent of SEL/IDL alarm
  history; flag devices running below their negotiated max link
  speed/width as degraded with a Warning event.
- Fall back to log/sel.csv (same format as selelist.csv) when selelist.csv
  is absent.
- Parse log/bmc/commer-comp/{commerslot,commerhmc,commerswvr,commerswcpld}
  logs (including rotated *.tar.gz.N parts) into failure events, filtering
  known-noisy lines.
- Collapse SEL events duplicated across sources by
  (timestamp, event_type, description).
- Surface a CollectionError when FRU/sensors are still empty after all
  fallbacks, instead of silently returning an empty inventory.
- Fix ParseFRU: a later placeholder "Product Serial : 0" / "Product Part
  Number : NULL" line in the same FRU block (e.g. SCM_FRU) was overwriting
  an already-parsed real Board Serial/Part Number.

Verified against dump_23DB01633_20260727-1359.tar.gz (HGX B200, KR9288-X3):
fru 0→21, sensors 0→303, 8 GPUs present at Gen5 x16 in slots 100-107.

Deferred (not covered by this change): BIOS-change-settings context and
BIOS POST codes from the same layout — see bible-local/10-decisions.md
ADL-048.

Co-Authored-By: Claude Sonnet 5 <noreply@anthropic.com>
2026-07-29 10:05:58 +03:00
Mikhail ChusavitinandClaude Sonnet 5 5677c49998 fix(parser): support Inspur onekeylog per-file component/*.txt D-Bus layout
Some onekeylog BMC firmware variants split the combined component.log
into per-file D-Bus GetAll transcripts under component/ (e.g.
PowerSupplyInfo.txt, FanInfo.txt), which the inspur parser did not
read, leaving PSU and fan data empty. Add a GETALL block parser and
wire it as a fallback for PSU and fan telemetry when component.log is
absent; document the layout and known gaps in bible-local.

Co-Authored-By: Claude Sonnet 5 <noreply@anthropic.com>
2026-07-23 12:24:17 +03:00
Mikhail ChusavitinandClaude Sonnet 4.6 a18d8fe648 feat(inspur): enrich storage serials from SOLHostCapture.log smartd output
When the BMC HDD API returns an empty array (RAID controller attached via
PCIe, e.g. PM8204-2GB), disk serial numbers are now recovered from smartd
startup messages in SOLHostCapture.log.

Enrichment runs in three passes: model-match on existing slots, positional
fill of empty backplane placeholders, then new entries for any remainder.
Both log/ and runningdata/var/ copies are merged with serial deduplication.

Parser version bumped to 2.1.

Co-Authored-By: Claude Sonnet 4.6 <noreply@anthropic.com>
2026-06-15 17:52:07 +03:00
Mikhail ChusavitinandClaude Sonnet 4.6 27373aa104 feat: surface BMC collection errors in parse-errors panel and event log
When Inspur component.log sections return {"error":"...","code":N} instead
of hardware data, the parser now:
- stores them in AnalysisResult.CollectionErrors (new model field)
- mirrors each one into result.Events with Source="BMC/<section>"
  so the chart viewer event table shows the specific BMC module
- feeds them into /api/parse-errors as bmc_collection_error entries

UI adds a collapsible "Collection diagnostics" panel below the chart
iframe (outside /chart) that appears when /api/parse-errors returns
any items; resets on data clear.

Affected sections in this dump: HDD (1458), PCIe Devices (1458),
Network Adapters (1458), Disk Backplane.

Co-Authored-By: Claude Sonnet 4.6 <noreply@anthropic.com>
2026-05-21 14:30:01 +03:00
Mikhail ChusavitinandClaude Sonnet 4.6 f2c04cf0e8 fix(inspur): parse CPUs from component.log and fix DIMM present detection
Two bugs in onekeylog archives that lack asset.json:

- CPU count was always 0: ParseComponentLog never parsed the "RESTful CPU
  info" section. Added parseCPUInfo as a fallback when hw.CPUs is empty
  (asset.json remains the primary source when present). Also worked around
  a Go JSON case-insensitive collision between "proc_id" (int) and
  "PROC_ID" (string CPUID) by adding an explicit PROC_ID field with an
  exact-case tag.

- Only 1 of 2 DIMMs shown: Present condition required mem_mod_size > 0,
  but some BMC firmware reports size=0 for a physically installed module
  while still providing serial and part number. Now treats a DIMM as
  present when status=1 and any of size/serial/partnum is non-empty.

Co-Authored-By: Claude Sonnet 4.6 <noreply@anthropic.com>
2026-05-21 14:13:55 +03:00
Mikhail Chusavitin 476630190d export: align reanimator contract v2.7 2026-03-15 23:27:32 +03:00
Mikhail ChusavitinandClaude Sonnet 4.6 9df29b1be9 fix: dedup GPUs across multiple chassis PCIeDevice trees in Redfish collector
Supermicro HGX exposes each GPU under both Chassis/1/PCIeDevices and a
dedicated Chassis/HGX_GPU_SXM_N/PCIeDevices. gpuDocDedupKey was keying
by @odata.id path, so identical GPUs with the same serial were not
deduplicated across sources. Now stable identifiers (serial → BDF →
slot+model) take priority over path.

Also includes Inspur parser improvements: NVMe model/serial enrichment
from devicefrusdr.log and audit.log, RAID drive slot normalization to
BP notation, PSU slot normalization, BMC/CPLD/VR firmware from RESTful
version info section, and parser version bump to 1.8.

Co-Authored-By: Claude Sonnet 4.6 <noreply@anthropic.com>
2026-03-06 14:44:36 +03:00
mchusandClaude Sonnet 4.6 21ea129933 misc: sds format support, convert limits, dell dedup, supermicro removal, bible updates
Parser / archive:
- Add .sds extension as tar-format alias (archive.go)
- Add tests for multipart upload size limits (multipart_limits_test.go)
- Remove supermicro crashdump parser (ADL-015)

Dell parser:
- Remove GPU duplicates from PCIeDevices (DCIM_VideoView vs DCIM_PCIDeviceView
  both list the same GPU; VideoView record is authoritative)

Server:
- Add LOGPILE_CONVERT_MAX_MB env var for independent convert batch size limit
- Improve "file too large" error message with current limit value

Web:
- Add CONVERT_MAX_FILES_PER_BATCH = 1000 cap
- Minor UI copy and CSS fixes

Bible:
- bible-local/06-parsers.md: add pci.ids enrichment rule (enrich model from
  pciids when name is empty but vendor_id+device_id are present)
- Sync bible submodule and local overview/architecture docs

Co-Authored-By: Claude Sonnet 4.6 <noreply@anthropic.com>
2026-03-01 22:23:44 +03:00
mchus 4940cd9645 sync file-type support across upload/convert and fix collected_at timezone handling 2026-02-28 23:27:49 +03:00
mchus e0146adfff Improve Redfish recovery flow and raw export timing diagnostics 2026-02-28 16:55:58 +03:00
mchus 9a30705c9a improve redfish collection progress and robust hardware dedup/serial parsing 2026-02-28 16:07:42 +03:00
mchus 758fa66282 feat: improve inspur parsing and pci.ids integration 2026-02-17 18:09:36 +03:00
mchus 514da76ddb Update Inspur parsing and align release docs 2026-02-15 23:13:47 +03:00
mchus 5e49adaf05 Update parser and project changes 2026-02-15 22:02:07 +03:00
Mikhail ChusavitinandClaude Sonnet 4.5 21f4e5a67e v1.2.0: Enhanced Inspur/Kaytus parser with GPU, PCIe, and storage support
Major improvements:
- Add CSV SEL event parser for Kaytus firmware format
- Add PCIe device parser with link speed/width detection
- Add GPU temperature and PCIe link monitoring
- Add disk backplane parser for storage bay information
- Fix memory module detection (only show installed DIMMs)

Parser enhancements:
- Parse RESTful PCIe Device info (max/current link width/speed)
- Parse GPU sensor data (core and memory temperatures)
- Parse diskbackplane info (slot count, installed drives)
- Parse SEL events from CSV format (selelist.csv)
- Fix memory Present status logic (check mem_mod_status)

Web interface improvements:
- Add PCIe link degradation highlighting (red when current < max)
- Add storage table with Present status and location
- Update memory specification to show only installed modules with frequency
- Sort events from newest to oldest
- Filter out N/A serial numbers from display

Co-Authored-By: Claude Sonnet 4.5 <noreply@anthropic.com>
2026-01-30 12:30:18 +03:00
mchusandClaude Opus 4.5 c7422e95aa v1.1.0: Parser versioning, server info, auto-browser, section overviews
- Add parser versioning with Version() method and version display on main screen
- Add server model and serial number to Configuration tab and TXT export
- Add auto-browser opening on startup with --no-browser flag
- Add Restart and Exit buttons with graceful shutdown
- Add section overview stats (CPU, Power, Storage, GPU, Network)
- Change PCIe Link display to "x16 PCIe Gen4" format
- Add Location column to Serials section
- Extract BoardInfo from FRU and PlatformId from ThermalConfig

Co-Authored-By: Claude Opus 4.5 <noreply@anthropic.com>
2026-01-25 13:49:43 +03:00
mchusandClaude Opus 4.5 512957545a Add LOGPile BMC diagnostic log analyzer
Features:
- Modular parser architecture for vendor-specific formats
- Inspur/Kaytus parser supporting asset.json, devicefrusdr.log,
  component.log, idl.log, and syslog files
- PCI Vendor/Device ID lookup for hardware identification
- Web interface with tabs: Events, Sensors, Config, Serials, Firmware
- Server specification summary with component grouping
- Export to CSV, JSON, TXT formats
- BMC alarm parsing from IDL logs (memory errors, PSU events, etc.)

Co-Authored-By: Claude Opus 4.5 <noreply@anthropic.com>
2026-01-25 04:11:23 +03:00