Move logpile to git.mchus.pro/reanimator/parser/v38 v38.0.0 (ADL-085).
Add scripts/bump-parser.sh, which bumps the parser, tests, commits, tags
the release as v<counter>.<parser major>, pushes and builds (ADL-086).
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Topology mapped one NUMA node per CPU, so on a 2-socket SNC2 host
(nodes 0-3) node 1 went to CPU1 and nodes 2-3 got no CPU: the second
BlueField-3, four GPUs and several NICs rendered unattached.
Use numa-nodes.txt (node=N package=P), now carried by parser v26 as
TopologyEvidence.NUMANodes; without it, fall back to contiguous
per-socket blocks of zero-based node ids. Pin parser v26.0.0. ADL-082.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
logpile no longer carries its own archive/vendor parsers or Redfish
raw-payload replay/analysis engine. Both now live in
git.mchus.pro/reanimator/parser/v13 (already used by the sibling `core`
project), reached through parser.NewService().AnalyzeArchivePayload /
AnalyzeRedfishRawPayloads. logpile keeps live BMC/Redfish collection,
the DB, exporter, server and UI.
- Deleted internal/parser/ (interface, registry, archive extraction,
all vendor packages), internal/collector/redfish_replay*.go (replay
engine, confirmed near-identical to the module's redfish/ package),
internal/ingest/ (pure duplicate of the module's Service),
internal/models/ (repointed every import to the module's models
package instead), and internal/rar5 (only used by the deleted
archive extractor). Removed the now-unused third_party/pciids
submodule.
- internal/collector/redfish.go: Collect() now calls
parser.NewService().AnalyzeRedfishRawPayloads(...) at the one place
it used to call the local ReplayRedfishFromRawPayloads (an existing
"unified tunnel" between live collection and raw import). A
deadcode-driven pass then removed ~150 doc-to-model conversion
helpers in redfish.go that duplicated the module's redfish/ package
and were already unreachable before this change; kept the small
generic dedup/scoring helpers the live crawler still calls.
- internal/collector/redfishprofile/ stays whole: Collect() depends on
it directly for acquisition-time tuning. Its analysis-only methods
(ApplyAnalysisProfiles/PostAnalyze) are now dead but left in place
rather than splitting the package's single Profile interface.
- pciids moved with the module (now a public package there); logpile's
live collector and exporter import it from there instead of keeping
a local copy.
- go.mod: new require on git.mchus.pro/reanimator/parser/v13 v13.0.0
(plain module dependency, not a submodule like reanimator/chart,
since this module is independently versioned and shared with core).
- bible-local docs rewritten for the new boundary; see ADL-080.
See also the companion change in git.mchus.pro/reanimator/parser
(tagged v13.0.0): new top-level exports
(IsSupportedArchiveFilename/SupportedArchiveExtensions/
ParseInDefaultArchiveLocation/PrivacyScanEnabled) and pciids moved to
a public package, both needed to complete this migration.
Co-Authored-By: Claude Sonnet 5 <noreply@anthropic.com>
NF-series storage servers (e.g. NF5280M6) have no GPU/outboard-PCIe
topology, so the previous score gate (topologyScore==0 || boardScore==0
→ return 0) always produced score=0 despite SystemManufacturer="Inspur"
being available. These servers fell into mode=fallback, activating the
AMI profile and probing /Oem/Ami paths that don't exist on the BMC.
Add manufacturer-based detection: SystemManufacturer or
ChassisManufacturer containing "inspur" contributes 60 points —
enough to enter matched mode on its own. GPU servers with full
topology+board signals still score higher as before.
Co-Authored-By: Claude Sonnet 4.6 <noreply@anthropic.com>
Lenovo ThinkSystem SR650 V3 (and similar XCC-based servers) caused
collection runs of 23+ minutes because the BMC exposes two large high-
error-rate subtrees in the snapshot BFS:
- Chassis/1/Sensors: 315 individual sensor members, 282/315 failing,
~3.7s per request → ~19 minutes wasted. These documents are never
read by any LOGPile parser (thermal/power data comes from aggregate
Chassis/*/Thermal and Chassis/*/Power endpoints).
- Chassis/1/Oem/Lenovo: 75 requests (LEDs×47, Slots×26, etc.),
68/75 failing → 8+ minutes wasted on non-inventory data.
Add a Lenovo profile (matched on SystemManufacturer/OEMNamespace "Lenovo")
that sets SnapshotExcludeContains to block individual sensor documents and
non-inventory Lenovo OEM subtrees from the snapshot BFS queue. Also sets
rate policy thresholds appropriate for XCC BMC latency (p95 often 3-5s).
Add SnapshotExcludeContains []string to AcquisitionTuning and check it
in the snapshot enqueue closure in redfish.go.
Co-Authored-By: Claude Sonnet 4.6 <noreply@anthropic.com>
- Add HPE iLO Redfish profile (priority 20): matches on manufacturer/OEM/iLO signals,
adds SmartStorage/SmartStorageConfig to critical paths, sets realistic ETA baseline
and rate policy for iLO's known slowness
- Fix post-probe hang on HPE iLO: skip numeric probing of collections where
Members@odata.count == len(Members); add 4s postProbeClient timeout as safety net
- Exclude /WorkloadPerformanceAdvisor from crawl paths
- Fix replay parser: skip absent CPU sockets, absent DIMM slots, absent drive bays
- Filter N/A version entries from firmware inventory
- Remove drive firmware from general firmware list (already in Storage[].Firmware)
- Add HPE AHS (.ahs) archive parser with hybrid SMBIOS/Redfish extraction
Co-Authored-By: Claude Sonnet 4.6 <noreply@anthropic.com>
BMC readiness after power-on (waitForStablePoweredOnHost):
- After initial 1m stabilization, poll BMC inventory readiness before collecting
- Ready if MemorySummary.TotalSystemMemoryGiB > 0 OR PCIeDevices.Members non-empty
- On failure: wait +60s, retry; on second failure: wait +120s, retry; then warn and proceed
- Configurable via LOGPILE_REDFISH_BMC_READY_WAITS (default: 60s,120s)
Empty critical collection plan-B retry (EnableEmptyCriticalCollectionRetry):
- Hardware inventory collections that returned Members=[] are now re-probed in plan-B
- Covers PCIeDevices, NetworkAdapters, Processors, Drives, Storage, EthernetInterfaces
- Enabled by default in generic profile (applies to all vendors)
Ghost NIC dedup fix (enrichNICsFromNetworkInterfaces):
- NetworkInterface entries (e.g. Id=2) that don't match existing NIC slots are now
resolved via Links.NetworkAdapter cross-reference to the real Chassis NIC
- Prevents duplicate ghost entries (slot=2 "Network Device View") from appearing
alongside real NICs (slot="RISER 5 slot 1 (7)") with the same MAC addresses
Co-Authored-By: Claude Sonnet 4.6 <noreply@anthropic.com>
- Collect hardware event logs (last 7 days) from Systems and Managers/SEL LogServices
- Parse AMI raw IPMI dump messages into readable descriptions (Sensor_Type: Event_Type)
- Filter out audit/journal/non-hardware log services; only SEL from Managers
- MSI ghost GPU filter: exclude processor GPU entries with temperature=0 when host is powered on
- Reanimator collected_at uses InventoryData/Status.LastModifiedTime (30-day fallback)
- Invalidate Redfish inventory CRC groups before host power-on
- Log inventory LastModifiedTime age in collection logs
- Drop SecureBoot collection (SecureBootMode, SecureBootDatabases) — not hardware inventory
- Add build version to UI footer via template
- Add MSI Redfish API reference doc to bible-local/docs/
ADL-032–ADL-035
Co-Authored-By: Claude Sonnet 4.6 <noreply@anthropic.com>
Matches on ServiceRootVendor "xFusion" and OEM namespace "xFusion"
(score 90+). Enables GenericGraphicsControllerDedup unconditionally and
ProcessorGPUFallback when GPU-type processors are present in the snapshot
(xFusion G5500 V7 exposes H200s simultaneously in PCIeDevices,
GraphicsControllers, and Processors/Gpu* — all three need dedup).
Without this profile, xFusion fell into fallback mode which activated all
vendor profiles (Supermicro, HGX, MSI, Dell) unnecessarily. Now resolves
to matched mode with targeted acquisition tuning (120k cap, 75s baseline).
Co-Authored-By: Claude Sonnet 4.6 <noreply@anthropic.com>
Implement the full architectural plan: unified ingest.Service entry point
for archive and Redfish payloads, modular redfishprofile package with
composable profiles (generic, ami-family, msi, supermicro, dell,
hgx-topology), score-based profile matching with fallback expansion mode,
and profile-driven acquisition/analysis plans.
Vendor-specific logic moved out of common executors and into profile hooks.
GPU chassis lookup strategies and known storage recovery collections
(IntelVROC/HA-RAID/MRVL) now live in ResolvedAnalysisPlan, populated by
profiles at analysis time. Replay helpers read from the plan; no hardcoded
path lists remain in generic code.
Also splits redfish_replay.go into domain modules (gpu, storage, inventory,
fru, profiles) and adds full fixture/matcher/directive test coverage
including Dell, AMI, unknown-vendor fallback, and deterministic ordering.
Co-Authored-By: Claude Sonnet 4.6 <noreply@anthropic.com>