fix(parser): support Inspur HGX dump_<serial>_<timestamp>/ onekeylog layout
Fixes #20. This onekeylog variant has no devicefrusdr.log at all: FRU/sensors come from raw ipmitool text output, PCIe/GPU presence has a dedicated structural snapshot, SEL lives at a different path, and BMC component failures are logged separately from SEL/IDL. - Fall back to component/fru.txt (same FRU block format as devicefrusdr.log) and component/sensor.txt / sdr.txt (ipmitool sensor list / sdr elist) when devicefrusdr.log is absent. - Parse log/bmc/diagnose/OtrdDiagnoseComponent.json's PCIe Device Info array for GPU/PCIe presence and link state, independent of SEL/IDL alarm history; flag devices running below their negotiated max link speed/width as degraded with a Warning event. - Fall back to log/sel.csv (same format as selelist.csv) when selelist.csv is absent. - Parse log/bmc/commer-comp/{commerslot,commerhmc,commerswvr,commerswcpld} logs (including rotated *.tar.gz.N parts) into failure events, filtering known-noisy lines. - Collapse SEL events duplicated across sources by (timestamp, event_type, description). - Surface a CollectionError when FRU/sensors are still empty after all fallbacks, instead of silently returning an empty inventory. - Fix ParseFRU: a later placeholder "Product Serial : 0" / "Product Part Number : NULL" line in the same FRU block (e.g. SCM_FRU) was overwriting an already-parsed real Board Serial/Part Number. Verified against dump_23DB01633_20260727-1359.tar.gz (HGX B200, KR9288-X3): fru 0→21, sensors 0→303, 8 GPUs present at Gen5 x16 in slots 100-107. Deferred (not covered by this change): BIOS-change-settings context and BIOS POST codes from the same layout — see bible-local/10-decisions.md ADL-048. Co-Authored-By: Claude Sonnet 5 <noreply@anthropic.com>
This commit is contained in:
+9
-2
@@ -72,9 +72,16 @@ func ParseFRU(content []byte) []models.FRUInfo {
|
||||
current.ProductName = fieldValue
|
||||
}
|
||||
case "Board Serial", "Product Serial":
|
||||
current.SerialNumber = fieldValue
|
||||
// Modules with no product-level FRU (e.g. SCM_FRU) report
|
||||
// "Product Serial : 0" after a real "Board Serial" value;
|
||||
// don't let the placeholder overwrite the real serial.
|
||||
if fieldValue != "0" && fieldValue != "NULL" {
|
||||
current.SerialNumber = fieldValue
|
||||
}
|
||||
case "Board Part Number", "Product Part Number":
|
||||
if fieldValue != "0" {
|
||||
// See "Board Serial" above: placeholder "NULL"/"0" product-level
|
||||
// fields must not overwrite a real board-level part number.
|
||||
if fieldValue != "0" && fieldValue != "NULL" {
|
||||
current.PartNumber = fieldValue
|
||||
}
|
||||
case "Product Version":
|
||||
|
||||