feat(export): contract-conformant event_logs event_time and is_active
Reanimator contract v2.13 makes event_logs[].event_time optional
(Reanimator falls back to collection/ingest time) and defines is_active
("still active / not cleared").
- Omit event_time when the event has no source time instead of passing
collected_at off as the event time.
- is_active=true only from an authoritative active-alarm snapshot: Inspur
dev_status.log (IDL event ID / SEL sensor at the same instant) and
component.log fan state (new models.Event.Active). false for Deasserts,
superseded Asserts in a real Assert/Deassert lifecycle and Inspur
Warning/Critical Asserts missing from dev_status.log; unset otherwise.
A missing Deassert is not treated as active: AC loss and BMC resets drop
them (24C319575: PSU1 predictive failure).
- component.log fan events use source BMC instead of host.
- Request installed_at in the Reanimator contract to date component
installs from maintenance.log; follow-up in BACKLOG [installed_at].
ADL-072.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
This commit is contained in:
1 parent
693906ceba
commit
2ce60280c3
10 files changed
+423
-11
No files matched your search
+5
-3
@@ -48,8 +48,8 @@ func ParseComponentLog(content []byte, hw *models.HardwareConfig) {
|
||||
|
||||
// ParseComponentLogEvents extracts fan state reported in component.log.
|
||||
// It is a snapshot at log collection, not a journal entry: events carry no
|
||||
// timestamp. DIMM state is not emitted here: it lives on the DIMM itself
|
||||
// (see applyMemoryStatusFromEvents).
|
||||
// timestamp and are marked active. DIMM state is not emitted here: it lives
|
||||
// on the DIMM itself (see applyMemoryStatusFromEvents).
|
||||
func ParseComponentLogEvents(content []byte) []models.Event {
|
||||
return parseFanEvents(string(content))
|
||||
}
|
||||
@@ -1073,15 +1073,17 @@ func parseFanEvents(text string) []models.Event {
|
||||
severity = models.SeverityCritical
|
||||
}
|
||||
|
||||
active := true
|
||||
events = append(events, models.Event{
|
||||
ID: fmt.Sprintf("fan_%d_status", fan.ID),
|
||||
Source: "Fan",
|
||||
Source: "BMC",
|
||||
SensorType: "fan",
|
||||
SensorName: name,
|
||||
EventType: "Fan Status",
|
||||
Severity: severity,
|
||||
Description: fmt.Sprintf("%s reports %s", name, status),
|
||||
RawData: fmt.Sprintf("rpm=%d pct=%d model=%s", fan.SpeedRPM, fan.SpeedPercent, fan.FanModel),
|
||||
Active: &active,
|
||||
})
|
||||
}
|
||||
|
||||
|
||||
Reference in new issue
Block a user