feat: adaptive BMC readiness check + ghost NIC dedup fix + empty collection plan-B retry
BMC readiness after power-on (waitForStablePoweredOnHost): - After initial 1m stabilization, poll BMC inventory readiness before collecting - Ready if MemorySummary.TotalSystemMemoryGiB > 0 OR PCIeDevices.Members non-empty - On failure: wait +60s, retry; on second failure: wait +120s, retry; then warn and proceed - Configurable via LOGPILE_REDFISH_BMC_READY_WAITS (default: 60s,120s) Empty critical collection plan-B retry (EnableEmptyCriticalCollectionRetry): - Hardware inventory collections that returned Members=[] are now re-probed in plan-B - Covers PCIeDevices, NetworkAdapters, Processors, Drives, Storage, EthernetInterfaces - Enabled by default in generic profile (applies to all vendors) Ghost NIC dedup fix (enrichNICsFromNetworkInterfaces): - NetworkInterface entries (e.g. Id=2) that don't match existing NIC slots are now resolved via Links.NetworkAdapter cross-reference to the real Chassis NIC - Prevents duplicate ghost entries (slot=2 "Network Device View") from appearing alongside real NICs (slot="RISER 5 slot 1 (7)") with the same MAC addresses Co-Authored-By: Claude Sonnet 4.6 <noreply@anthropic.com>
This commit is contained in:
@@ -205,6 +205,9 @@ func ensureRecoveryPolicy(plan *AcquisitionPlan, policy AcquisitionRecoveryPolic
|
||||
if policy.EnableProfilePlanB {
|
||||
plan.Tuning.RecoveryPolicy.EnableProfilePlanB = true
|
||||
}
|
||||
if policy.EnableEmptyCriticalCollectionRetry {
|
||||
plan.Tuning.RecoveryPolicy.EnableEmptyCriticalCollectionRetry = true
|
||||
}
|
||||
}
|
||||
|
||||
func ensureScopedPathPolicy(plan *AcquisitionPlan, policy AcquisitionScopedPathPolicy) {
|
||||
|
||||
Reference in New Issue
Block a user